Specifications
Electrical
Operating Voltage
10 to 30V dc
Input Current Max
40 mA (RMS) @ 10 Vdc
1.2 A max peak current @ 10 Vdc at
startup for max duration = 100 ms
Power Consumption Max
1 W (RMS) @ 30 Vdc
Raster Width
Software adjustable from 10° to 40°
Oscillation Frequency
Software adjustable from 0.5 Hz to 4 Hz
Response Time
1 second max
Environmental
Operating Temperature
0 to +45 °C (+32 to +113 °F)
Storage Temperature
-20 to +70 °C (-4 to +158 °F)
Humidity Max
90% non condensing
Vibration Resistance (EN 60068-2-6)
-14 mm @ 2-10 Hz
-1.5 mm @ 13-55 Hz
-2 g @ 70-200 Hz
-2 hours on each axis
Bump Resistance (EN 60068-2-29)
30 g; 6 ms;
5000 shocks on each axis
Shock Resistance (EN 60068-2-27)
30 g; 11 ms;
3 shocks on each axis
Protection Class (EN 60529)
IP65 (when correctly mounted to the
scanner)
Physical Features
Dimensions
68 x 43 x 51.2 mm (2.68 x 1.69 x 2.02 in)
Weight
Approximately 160 g. (5.7 oz)
The features indicated are to be considered typical at an ambient temperature of 25 °C (77 °F), if