Environmental

Operating Humidity: 95% max. relative (non-condens-
ing)
Radiated Immunity: 10 V/m, 80-2700 MHz
(EN61000-6-2)

Included with Model

The following items ship with the DX80 radios.

• BWA-HW-002: DX80 Access Hardware Kit, containing four PG-7 plastic threaded plugs, four PG-7 nylon gland fittings, four PG-7 hex

nuts, one 1/2-inch NPT plug, and one 1/2-inch nylon gland fitting. (Not included with IP20 DX80...C models)

• BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws, four M5-0.8mm

SS hex nuts, and four #8-32 x 3/4" SS bolts

• BWA-HW-003: PTFE tape
• BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not included with Internal

antenna models)

• Quick Start Guide (128185 for DX80 Gateways or 152653 for MultiHop models)
• MQDC1-506: 5-Euro (single ended) straight cable, 2m (Not included with FlexPower devices)
• BWA-HW-011: IP20 Screw Terminal Headers (2 pack) (Included only with the IP20 DX80...C models)

Warnings

The manufacturer does not take responsibility for the violation of any warning listed in this document.
Make no modifications to this product. Any modifications to this product not expressly approved by Banner Engineering could void the
user’s authority to operate the product. Contact the Factory for more information.
All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of prod-
ucts without notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of
any documentation, refer to our website: 

www.bannerengineering.com

©

 2006-2010 Banner Engineering Corp. All rights reserved.

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned
to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse,
abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN-
CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND
WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL
BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPEN-
SES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY
PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR-
RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or
liabilities relating to any product previously manufactured by Banner Engineering Corp.

 

 

SureCross Performance FlexPower Node

 

www.bannerengineering.com - tel: 763-544-3164

 

Summary of Contents for SureCross Performance DX80N9X2S-P3 FlexPower

Page 1: ...te list of accessories refer to Banner Engineering s website www bannerengineering com surecross Models Frequency Power Housing I O DX80N9X2S P3 900 MHz ISM Band 10 to 30V dc or battery supply mod ule...

Page 2: ...its Modbus RTU RS 485 connection is a Modbus slave to a Modbus RTU host controller the wireless network may contain up to 47 Nodes in a single wireless network and the Gateway holds the Modbus regist...

Page 3: ...To access the internal DIP switches follow these steps 1 Unscrew the four screws that mount the cover to the bottom housing 2 Remove the cover from the housing without damaging the ribbon cable or the...

Page 4: ...600 degrees Fahrenheit or 1600 degrees Celsius switch the DIP switch to the ON position and use low resolution mode In high resolution the device cannot store values larger than 1600 Temperature Units...

Page 5: ...OUT x GND Ground dc common connection PWR Power 10 to 30V dc power connection DX80 C Wiring Wiring power to the DX80 C models varies depending the power requirements of the model Terminal Label Gatewa...

Page 6: ...optional 2 RS 485 D1 B RS 232 Tx 3 dc common GND dc common GND 4 RS 485 D0 A RS 232 Rx The BAT connection is a low voltage connection to the internal battery Remove the internal battery if a low volta...

Page 7: ...ocouples are available by configuring the Node Thermocouple Range F Range C Type B 212 to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 38...

Page 8: ...an integrated battery ship from the factory in storage mode to conserve the battery To wake the device press and hold button 1 for five seconds To put any FlexPower or integra ted battery SureCross r...

Page 9: ...isk of explosion if the battery is re placed incorrectly 4 After replacing the battery allow up to 60 seconds for the device to power up Properly dispose of your used battery according to local regula...

Page 10: ...FF Condition PNP Less than 5V NPN Greater than 2V or open Thermocouple Inputs Sample Rate 8 seconds Report Rate 32 seconds Accuracy 0 1 of full scale reading 0 8 C Resolution 0 1 C 24 bit A D converte...

Page 11: ...the most recent version of any documentation refer to our website www bannerengineering com 2006 2010 Banner Engineering Corp All rights reserved Banner Engineering Corp Limited Warranty Banner Engine...