![Banner SureCross DX81 Specification Sheet Download Page 3](http://html1.mh-extra.com/html/banner/surecross-dx81/surecross-dx81_specification-sheet_471907003.webp)
DX81 and DX81H FlexPower Module Battery Replacement
For outside or high humidity environments, conductive grease may be applied to the battery terminals to prevent moisture and corrosion
buildup.
To replace the lithium "D" cell battery in the DX81 FlexPower
™
battery kit, follow these steps.
1. Unplug the battery device from the SureCross device it powers.
2. Remove the four screws mounting the battery pack face plate to the body and remove
the face plate.
3. Remove the discharged battery and replace with a new battery. Only use a 3.6V lithium
battery from Xeno, model number XL-205F.
4. Verify the battery’s positive and negative terminals align to the positive and negative ter-
minals of the battery holder mounted within the case. Caution: There is a risk of explo-
sion if the battery is replaced incorrectly.
5. After replacing the battery, allow up to 60 seconds for the device to power up.
When removing the battery, press the battery towards the negative terminal to compress the
spring. Pry up on the battery’s positive end to remove from the battery holder. Properly dispose
of your used battery according to local regulations by taking it to a hazardous waste collection
site, an e-waste disposal center, or any other facility qualified to accept lithium batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose
them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to
water.
Replacement battery model number: BWA-BATT-001. For pricing and availability, contact Banner Engineering.
Specifications
General
Estimated Battery Life
19,000 mA·hours
Housing
Polycarbonate
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 in·lbf)
Wiring Access
One 1/2-inch NPT with 5-pin Euro-style 150mm pigtail
QD
Environmental
Environmental
Rating: IEC IP67; NEMA 6; (See UL section below for
any applicable UL specifications)
Operating Temperature: −40 to +85° C
Operating Humidity: 95% max. relative (non-condens-
ing)
Radiated Immunity: 10 V/m, 80-2700 MHz
(EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
Refer to the SureCross
™
DX80 Wireless I/O Network product manual, Banner p/n 132607, for installation and waterproofing instructions.
Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Warnings
The manufacturer does not take responsibility for the violation of any warning listed in this document.
Make no modifications to this product. Any modifications to this product not expressly approved by Banner Engineering could void the
user’s authority to operate the product. Contact the Factory for more information.
SureCross DX81 FlexPower Supply Module
P/N 131596 rev. D
www.bannerengineering.com - tel: 763-544-3164