background image

For outside or high humidity environments, dielectric grease may be applied to the battery terminals to

prevent moisture and corrosion buildup.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose them to

high temperatures. Do not recharge, crush, disassemble, or expose the contents to water.
For non-hazardous locations, the replacement battery is model BWA-BATT-011. For non-hazardous or

hazardous locations, the replacement battery is Xeno model XL-205F, Banner model BWA-BATT-001.

For pricing and availability, contact Banner Engineering.

Specifications

Performance Radio Specifications

Radio Range

1

900 MHz, 1 Watt: Up to 9.6 km (6 miles)

2.4 GHz, 65 mW: Up to 3.2 km (2 miles)

Antenna Minimum Separation Distance

900 MHz, 1 Watt: 4.57 m (15 ft)

2.4 GHz, 65 mW: 0.3 m (1 ft)

Radio Transmit Power

900 MHz, 1 Watt: 30 dBm (1 W) conducted (up to 36 dBm EIRP)

2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 20 dBm

(100 mW) EIRP

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

900 MHz Compliance (1 Watt)

FCC ID UE3RM1809: FCC Part 15, Subpart C, 15.247

IC: 7044A-RM1809

2.4 GHz Compliance

FCC ID UE300DX80-2400: FCC Part 15, Subpart C, 15.247

RED Directive 2014/53/EU

IC: 7044A-DX8024

Antenna Connection

Ext. Reverse Polarity SMA, 50 Ohms

Max Tightening Torque: 0.45 N·m (4 lbf·in)

Link Timeout

Gateway: Configurable via User Configuration Software

Node: Defined by Gateway

P16E Performance Node Specifications

Supply Voltage

10 V DC to 30 V DC (Outside the USA: 12 V DC to 24 V DC, ± 10%) with

integrated battery backup

Discrete Input

Rating: 3 mA max current at 30 V DC

Sample / Report Rates: DIP switch configurable

Discrete Input ON Condition

PNP: Greater than 10 V

NPN: Less than 0.7 V

Discrete Input OFF Condition

PNP: Less than 5 V

NPN: Greater than 2 V or open

Counter Input

Event counter: Input rating 1 Hz to 10 kHz (For battery powered devices, the

recommended input rating is less than 1 kHz)

Rate (frequency) counter: 1 Hz to 10 kHz

Debounce select will filter the higher frequencies

Thresholds:

PNP/NPN: See Discrete Input Conditions
Float: Selectable (1 V / 300 mV)

Wiring Access

Two 1/2-inch NPT

Current Draw at 3.6 V dc

900 MHz, 1 Watt: Average Runtime 320 µA

900 MHz, 250 mW: Average Runtime 270 µA

2.4 GHz, 65 mW: Average Runtime 250 µA

Housing

Polycarbonate housing and rotary dial cover; polyester labels; EDPM rubber

cover gasket; nitrile rubber, non-sulphur cured button covers

Mounting: 1/4-inch or M7 (SS M7 hardware included)

Max. Tightening Torque: 0.56 N·m (5 lbf·in)

Interface

Two bi-color LED indicators

Two buttons

Six character LCD

Certifications

(CE approval only

applies to 2.4 GHz

models)

(NOM approval only

applies to 900 MHz

models)

Environmental Specifications for the E Housing

Operating Conditions

–40 °C to +85 °C (–40 °F to +185 °F) (Electronics); –20 °C to +80 °C (–4 °F to

+176 °F) (LCD)

95% maximum relative humidity (non-condensing)

Radiated Immunity: 10 V/m (EN 61000-4-3)

Shock and Vibration

IEC 68-2-6 and IEC 68-2-27

Shock: 30g, 11 millisecond half sine wave, 18 shocks

Vibration: 0.5 mm p-p, 10 to 60 Hz

Environmental Ratings

IEC IP65

Refer to the Sure Cross

®

 Wireless I/O Networks Instruction Manual (p/n 

132607

) for installation and waterproofing instructions.

Operating the devices at the maximum operating conditions for

extended periods can shorten the life of the device.

1

Radio range is with the 2 dB antenna that ships with the product. High-gain antennas are available, but the range depends on the environment and line of sight. Always verify your wireless
network's range by performing a Site Survey.

Sure Cross

®

 Performance Universal Counter P16E Node

 

 

P/N 199134 Rev. D

www.bannerengineering.com - Tel: + 1 888 373 6767

7

Summary of Contents for Sure Cross P16E Series

Page 1: ...mentation technique complète des Performance Gateway or Node sur notre site www bannerengineering com pour les détails sur leur utilisation correcte les applications les notes de sécurité et les instructions de montage WARNING Do not use this device for personnel protection Using this device for personnel protection could result in serious injury or death This device does not include the self chec...

Page 2: ...to the Gateway 4 Form the wireless network by binding the Nodes to the Gateway If the binding instructions are not included in the datasheet refer to the product manual for binding instructions 5 Observe the LED behavior to verify the devices are communicating with each other For housed models the Gateway s LED 1 is solid green and the Node s LED 1 flashes green to indicate it is communicating wit...

Page 3: ...e Input Type PNP OFF ON Counter Discrete Value Input Type Float 1 V Threshold ON OFF Counter Discrete Value Input Type Float 300 mV Threshold ON ON Sample Report Rate 64 Seconds OFF OFF Sample Report Rate 16 Seconds OFF ON Sample Report Rate 4 Seconds ON OFF Sample Report Rate Modbus or UCT Configured ON ON Debounce Enabled OFF Debounce Disabled ON Counter 2 Input Type Event OFF Counter 2 Input Ty...

Page 4: ... for 2 4 GHz is fixed at about 65 mW EIRP 18 dBm making the 2 4 GHz Performance models automatically compatible with older 2 4 GHz models Wire for Power and I O XD4 XC4 CT2 PWR DO2 GND DO6 XC4 XC3 GND PWR DO5 DO1 XD3 XC3 CT1 CT1 Counter input 1 CT2 Counter input 2 DO1 NMOS output 1 DO2 NMOS output 2 DO5 NMOS output 5 DO6 NMOS output 6 PWR Power for sensors Counter Input Wiring for PNP Sensors Coun...

Page 5: ...21 0x1401 to clear counter 1 2 Write 5122 0x1402 to clear counter 2 3 Write 5123 0x1403 to clear counters 1 and 2 When you are not using a host controlled system a transition from 0 to 1 on the Node s output registers is needed to clear the counter Use this method on Gateway IO mapping to map inputs such as a push button to clear counter values 1 Write output register 13 from 0 to 1 to clear count...

Page 6: ... Node 8 Instance 112 N14 NMOS OUT 1 0 1 0 1 10 10 Node 16 1 Node 8 NMOS OUT 2 0 1 0 1 11 11 Node 16 2 Node 8 NMOS OUT 5 0 1 0 1 12 12 Node 16 3 Node 8 NMOS OUT 6 0 1 0 1 13 13 Node 16 4 Node 8 Clear Counter 1 0 1 0 1 14 14 Node 16 5 Node 8 Clear Counter 2 0 1 0 1 15 15 Node 16 6 Node 8 Control Message 16 16 Node 16 7 Node 8 Reserved Installing or Replacing the Battery DX80 E Models To replace the ...

Page 7: ...rete Input OFF Condition PNP Less than 5 V NPN Greater than 2 V or open Counter Input Event counter Input rating 1 Hz to 10 kHz For battery powered devices the recommended input rating is less than 1 kHz Rate frequency counter 1 Hz to 10 kHz Debounce select will filter the higher frequencies Thresholds PNP NPN See Discrete Input Conditions Float Selectable 1 V 300 mV Wiring Access Two 1 2 inch NPT...

Page 8: ... OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE US...

Reviews: