background image

 

Review the PC Interface screen

GeT STARTed

This QUICK START GUIDE will help you:

• Install

 the SC22-3 PC Interface (PCI) software

• Configure

 your application with the PCI

• Confirm

 your configuration

     

Take these items out of the kit

*

GeT SeT

GeT GOING

Confirm your configuration

Power the SC22-3 Controller, and 
connect it to the PC via the USB cable 
  Click “Save” to save configuration file
  Click “Confirm” in Tool Bar
   Enter Controller’s password  

(Default password is “0000”)

   Confirm each correct input or output 

parameter checkbox

   Click “OK” and push 

“System Reset” (or cycle power)

Install the software

  Insert CD into computer CD drive
  To install: run setup.exe, or click “Install Software” on launch menu
   Restart computer for maximum functionality  

On restart, Banner Safety Controller icon will appear on your desktop

  Double-click icon to launch PCI

Using the SC-XM1 external memory card

The external memory card stores one configuration and can be used to:

   • Configure a replacement Controller on the factory floor
   • Clone other Controllers without the use of a PC
   • Reconfigure an in-service Controller on the factory floor without the use of a PC

View finished system diagrams  

and summary with the  

CONFIGURATION DOCUMENTS

Create and manage your files with the 

TOOL BAR

Quickly review and access 

I/O property information 

with the 

I/O FILES

TOOL BAR

I/O FILES

CONFIGURATION 

DOCUMENTS

Wiring Diagram

Ladder Logic   

Diagram

Configuration 

Summary

1

Model Number Includes:

SC22-3-S

Screw terminals

SC22-3-C

Clamp terminals

SC22-3-SU1

Screw terminals, programming tool & USB cable

SC22-3-CU1

Clamp terminals, programming tool & USB cable

Base Model: SC22-3 Safety Controller, SC-XM1 Memory Card

1

2

3

4

System Requirements

Operating system

Windows

®

 XP, 2000, and Vista

®

Hard drive space

100 MB (plus up to 280 MB for Microsoft .NET 2.0, if not already installed)

Third-party software Microsoft .NET 2.0 (installs with PC Interface if not already on computer) 

Adobe

®

 Reader

®

 for Windows

®

 7.0 or newer

USB port

USB 1.1 or 2.0 type A port

2

3

ReSOuRceS

1-888-373-6767

www.bannerengineering.com

1

2

3

4

5

SC-USB1

USB A/B Cable

Plug-in Terminals

(SC-TS1 & SC-TC1)

 SC-XMP XM Card

USB Programming Tool

SC-XM1 External 

Memory Card

SC22-3 Safety Controller

 

CD

Set timing functions

  Click “Safety Outputs” in the Tool Bar

  Configure output properties:
     a. Select safety output     

b. Select delay type     
c. Specify delay time limit    
d. Click “OK”

Establish Status Output properties

Select “Status Outputs” from the Tool Bar 
and select any of the following:

• Track Input 

• System Waiting for Reset

• Track Output 

• Output Waiting for Reset

• System Lockout Status  • Mute Status
• I/O Fault Status 
  

Name and save your configuration

a.

b.

c.

d.

a.

b.

d.

c.

CAUTION! 

Thoroughly read the instruction 

manual before using this product in a  

safeguarding application.

Add a safety input

  Click “Add Safety Input” in the Tool Bar

  Select a device

  Modify device properties:
     a. Select device circuit type    

b. Select reset logic  
c. Map inputs and outputs    
d. Click “OK”

     This process may be used for either  
     safety or non-safety input devices.

Click “Systems Settings” 
in the Tool Bar

Enter configuration 
name and click “OK”

Click “Save” to save the 
configuration file

1

2

3

1

2

3

1

2

1

2
3

4

5

* Items included depend on model number.

Download:

Printed in USA 

08/07

 

P/N 133487

SC22-3 Safety Controller

Instruction Manual

Section Contents

Section 1 

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3 

Section 2 

Components and Specifications  . . . . . . . . . . . . . . . . . . . Page 8

Section 3 

Input Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 20

Section 4  

PC Interface Configurations. . . . . . . . . . . . . . . . . . . . . . Page 30

Section 5 

Controller Interface Configuration  . . . . . . . . . . . . . . . . . Page 40

Section 6 

Operating Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . Page 50

Section 7 

Periodic Checkout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 60

Section 8 

Troubleshooting and Maintenance. . . . . . . . . . . . . . . . . Page 70

Appendix A 

Input Device Reference . . . . . . . . . . . . . . . . . . . . . . . . . Page 80

Appendix B 

PCI Configuration Tutorial. . . . . . . . . . . . . . . . . . . . . . . . .  Page 85 

Appendix C 

OBI Configuration Tutorial . . . . . . . . . . . . . . . . . . . . . . . Page 90

 

Glossary  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 95

Features

•  Easy-to-use Controller with fully configurable inputs 

and outputs

•  ISO 13849-1 Category 2, 3, or 4 and OSHA/ANSI 

Control Reliability Input device hookup

• 22 Inputs for safety and non-safety input devices

•  3 dual channel Safety outputs with selectable ON- and 

OFF-delay

•  10 Status outputs track and signal input and output 

status, mute status, lockout, fault conditions and reset 
needed

•  Simple configuration procedure using PC interface 

(PCI) or on-board controller interface (OBI) maps each 
input device to any of 3 safety outputs

•  Configurations are confirmed before use, for assurance 

of safety integrity

•  Configurations are transferable to multiple SC22-3 

Controllers

• Password protected

• 24V dc operation

•  Complies with Safety Integrity Level (SIL) 3 per

IEC 62061 and IEC 61508, and Category 4 
Performance Level “e” per ISO 13849-1.

Manual 

P/N 133487 

Software 

P/N 134534 

Learn: 

Banner Engineering 

Machine Safety Online Training 

Buy:

Buy Banner Online 

Summary of Contents for SC22-3

Page 1: ...commission and maintain the system periodically throughout its working life fAILuRe TO dO SO cOuLd LeAd TO SeRIOuS INjuRy OR deATh SC22 3 Safety Controller QuIck START GuIde No other fonts are accepta...

Page 2: ...for Onboard Interface SC XM1 External Memory Card Flashing DIN Rail CAMERA READY LOGOTYPE OF THE UL MARK These Marks are registered by Underwriters Laboratories Inc UL UL UL The minimum height of the...

Page 3: ...Includes SC22 3 S Screw terminals SC22 3 C Clamp terminals SC22 3 SU1 Screw terminals programming tool USB cable SC22 3 CU1 Clamp terminals programming tool USB cable Base Model SC22 3 Safety Control...

Page 4: ...pear on your desktop Double click icon to launch PCI 1 2 3 4 System Requirements Operating system Windows XP 2000 and Vista Hard drive space 100 MB plus up to 280 MB for Microsoft NET 2 0 if not alrea...

Page 5: ...nd summary with the CONFIGURATION DOCUMENTS Create and manage your files with the TOOL BAR Quickly review and access I O property information with the I O FILES TOOL BAR I O FILES CONFIGURATION DOCUME...

Page 6: ...uration CAUTION Thoroughly read the instruction manual before using this product in a safeguarding application Click Systems Settings in the Tool Bar Enter configuration name and click OK Click Save t...

Page 7: ...d Safety Input in the Tool Bar Select a device Modify device properties a Select device circuit type b Select reset logic c Map inputs and outputs d Click OK This process may be used for either safety...

Page 8: ...utput properties a Select safety output b Select delay type c Specify delay time limit d Click OK Establish Status Output properties Select Status Outputs from the Tool Bar and select any of the follo...

Page 9: ...ct it to the PC via the USB cable Click Save to save configuration file Click Confirm in Tool Bar Enter Controller s password Default password is 0000 Confirm each correct input or output parameter ch...

Page 10: ...rnal memory card stores one configuration and can be used to Configure a replacement Controller on the factory floor Clone other Controllers without the use of a PC Reconfigure an in service Controlle...

Page 11: ...set Output delay options 10 status outputs Category 4 PL e and SIL 3 safeguarding applications E Stops Light Curtains Two Hand Controls Interlock Switches Manual Resets ON OFF Switches Non Safety Inpu...

Page 12: ...TED C UL US LISTED C UL US LISTED C UL US C LISTED C US UL UL US C LISTED UL US C LISTED UL US C LISTED The minimum height of the registered trademark symbol shall be 3 64 of an inch When the overall...

Page 13: ...able inputs and outputs ISO 13849 1 Category 2 3 or 4 and OSHA ANSI Control Reliability Input device hookup 22 Inputs for safety and non safety input devices 3 dual channel Safety outputs with selecta...

Page 14: ...together with the same UL Mark The word LISTED would only be used once either to the right of or below the UL Mark as shown The font for all letter forms is Helvetica Condensed Black except for the tr...

Page 15: ...products This warranty is in lieu of any other warranty either expressed or implied 200 195A 20M 3 02 LISTED LISTED 0 12 24 36 48 60 72 84 96 108 120 132 144 156 168 180 192 204 216 CAMERA READY LOGOT...

Reviews: