Note:
Teach modes must be set with the remote input wire.
To cancel a configuration while in process, press and hold the button for the output being taught for longer than 2 seconds.
1. To enter TEACH mode, press and hold the button for the desired output.
The buttons are
Analog
and
Discrete
(analog models) and
Discrete 1
and
Discrete 2
(discrete models).
The green Power LED turns OFF, the yellow LED of the output being taught turns ON, and the yellow LED of the
output not being taught turns OFF.
2. Position the target.
3. Press the button for the desired output one time to configure the first point.
The yellow LED of the output being taught flashes.
4. Position the target.
5. Press the button for the desired output one time to configure the second point.
The green Power LED turns on.
5.4 Remote Input
Use the remote input to program the sensor remotely.
The remote input provides limited programming options and is Active High. For Active High, connect the gray input wire to V
+ (10 V DC to 30 V DC), with a remote switch connected between the wire and ground. This can be configured for Active Low
in the Banner Radar Configuration software by changing the
Sensor Polarity
. For Active Low, connect the gray input wire to
ground (0 V DC).
The remote input wire is disabled by default. Pulse the remote input wire 10 times or use the Banner Radar Configuration
software to enable the feature. After enabling the remote input feature, pulse the remote input according to the diagram and
the instructions provided in this manual. Remote teach can also be performed using the button on the Pro Converter Cable.
The length of the individual programming pulses is equal to the value T:
0.04 seconds ≤ T ≤ 0.8 seconds
.
Exit remote programming modes by setting the remote input Low for longer than 2 seconds or by waiting for 60 seconds.
R-GAGE
®
T30R Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767