background image

Beam Pattern

Typical Beam Pattern (with BRTR-CC20E Radar

Target, Radar Cross Section = 50 m

2

)

Typical Beam Pattern (with 4 different targets)

0

0

-1

-2

-3

3

2

1

5

10

15

20

25

Meters

30

35

40

45

Meters

Sensitivity 1

Sensitivity 8

8

1

2

3

4

5

6

7

1–8: Indicates sensitivity level

0

0

-1

-2

-3

-4

-5

-6

4

3

6

5

2

1

5

10

15

20

25

Meters

30

35

40

45

Meters

Weak Object

Car

Large Truck

Passenger Train

4

3

2

1

At sensitivity level 8

1: Weak Object (Radar cross section = 0.25 m

2

)

2: Car (Radar cross section = 3 m

2

)

3: Large Truck (Radar cross section = 50 m

2

)

4: Passenger Train (Radar cross section = 300 m

2

)

0

0

-1

-2

-3

-4

-5

-6

4

3

6

5

2

1

5

10

15

20

25

Meters

30

35

40

45

Meters

Car

Large Truck

Passenger Train

4

3

2

Weak Object

(Trace Data)

1

At sensitivity level 4

NOTE: The effective beam pattern depends on the sensitivity level and target properties.

 

 

R-GAGE

 Q240RA-AF2 Sensor

6

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 184564 Rev. A

Summary of Contents for R-GAGE Q240RA-AF2

Page 1: ...ct Contact Banner Engineering for more information WARNING Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection Doing so could lead to serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energize...

Page 2: ... 3 5 m 11 5 ft Y Maximum Zone 1 setpoint distance 30 m 98 4 ft 30 m 98 4 ft A Minimum Zone 2 offset from Zone 1 2 m to 25 m 4 m 13 1 ft 5 5 m 18 0 ft B Maximum Zone 2 offset from Zone 1 2 m to 25 m 55 m 180 4 ft 55 m 180 4 ft D Dead Zone1 Sensor Configuration Use the included spanner to open the screw off cover on the side of the sensor and access the DIP switches Important Tighten the DIP switch ...

Page 3: ...4 Distance CN US 0 0 0 0 2 m 6 6 ft 3 5 m 11 5 ft 0 0 0 1 2 5 m 8 2 ft 4 m 13 1 ft 0 0 1 0 3 m 9 8 ft 4 5 m 14 8 ft 0 0 1 1 3 5 m 11 5 ft 5 m 16 4 ft 0 1 0 0 4 m 13 1 ft 5 5 m 18 0 ft 0 1 0 1 5 m 16 4 ft 6 m 19 7 ft 0 1 1 0 6 m 19 7 ft 6 5 m 21 3 ft 0 1 1 1 7 m 23 0 ft 7 m 23 0 ft 1 0 0 0 8 m 26 2 ft 8 m 26 2 ft 1 0 0 1 10 m 32 8 ft 10 m 32 8 ft 1 0 1 0 12 m 39 4 ft 12 m 39 4 ft 1 0 1 1 14 m 45 9 ...

Page 4: ...3 Sensitivity 0 0 0 8 Highest 0 0 1 7 0 1 0 6 High 0 1 1 5 1 0 0 4 Medium 1 0 1 3 1 1 0 2 Low 1 1 1 1 Lowest Default settings NOTE Operation at a high sensitivity not guaranteed for a zone set beyond 45 m 147 6 ft Output Configuration A8 NPN PNP 0 NPN 1 PNP Default settings B7 Normally Open Closed 0 NO 1 NC Response Speed B4 B5 B6 ON Total ms OFF Total ms Total ms 0 0 0 15 15 30 0 0 1 30 70 100 0 ...

Page 5: ...d configuration See Overview on page 1 Adjustments DIP switch configurable sensing distance sensitivity response time and output configuration Construction Housing Polycarbonate Lightpipes Acrylic Access Cap Polyester Operating Temperature 40 to 65 C 40 to 149 F Environmental Rating IP67 Connections Integral M12 Euro style QD fitting QD models require a mating cordset Certifications CMIIT Category...

Page 6: ...ar Large Truck Passenger Train 4 3 2 1 At sensitivity level 8 1 Weak Object Radar cross section 0 25 m2 2 Car Radar cross section 3 m2 3 Large Truck Radar cross section 50 m2 4 Passenger Train Radar cross section 300 m2 0 0 1 2 3 4 5 6 4 3 6 5 2 1 5 10 15 20 25 Meters 30 35 40 45 Meters Car Large Truck Passenger Train 4 3 2 Weak Object Trace Data 1 At sensitivity level 4 NOTE The effective beam pa...

Page 7: ...repeat every 6 1 mm of distance between the sensor and the window The positions of maximum reflection from the window repeat between the minimums and decrease in effect until the window is approximately 150 mm 5 9 in away Consult the factory for pre tested window materials which can be used at any distance without issue Additionally the face of the window should be protected from flowing water and...

Page 8: ...2 White 3 Blue 4 Black 5 Gray MQDEC2 515 4 57 m 15 ft MQDEC2 530 9 14 m 30 ft MQDEC2 550 15 2 m 50 ft MQDEC2 506RA 1 83 m 6 ft Right Angle 32 Typ 1 26 30 Typ 1 18 ø 14 5 0 57 M12 x 1 MQDEC2 515RA 4 57 m 15 ft MQDEC2 530RA 9 14 m 30 ft MQDEC2 550RA 15 2 m 50 ft NOTE Pin 5 is not used Brackets and Other Accessories SMBQ240SS2 Add on accessory to be used in conjunction with SMBQ240SS1 Provides 20 of ...

Page 9: ... AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIAB...

Reviews: