Page 1: ...R GAGE Q130RA AF Sensor Instruction Manual Original Instructions TBD Rev A 31 October 2018 Banner Engineering Corp All rights reserved TBD D R A F T ...

Page 2: ... Installation Instructions 5 2 1 Mount the Device 5 2 2 Wiring 5 3 Specifications 6 3 1 Beam Patterns 6 3 2 Dimensions 7 4 Windows 8 5 Accessories 9 5 1 Quick Disconnect QD Cordsets 9 5 2 Brackets and Enclosures 9 6 Banner Engineering Corp Limited Warranty 10 R GAGE Q130RA AF Sensor D R A F T ...

Page 3: ...ld lead to serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energized or de energized sensor output condition 1 1 Models Models Maximum Range Beam Angle Telecom Approval1 Output Connection Q130RA 9076 AFQ 24 m 78 ft 90 76 Telecom approved for US ...

Page 4: ...R GAGE Features 1 Power LED Green power ON 2 Signal Strength LED Red flashes in proportion to the signal strength 3 Output LEDs Yellow output energized Red configuration R GAGE Q130RA AF Sensor 4 www bannerengineering com Tel 1 763 544 3164 D R A F T ...

Page 5: ...alignment 4 Tighten the mounting screws to secure the device or the device and the bracket in the aligned position 2 2 Wiring shield QD cordset 3 1 2 4 5 12 30V dc Load 1 Load 2 Wiring Key 1 Brown 2 White 3 Blue 4 Black 5 Gray Do not connect Note Banner recommends that the shield wire QD cordsets only be connected to earth ground or dc common Shielded cordsets are recommended for all QD models R G...

Page 6: ...rgized Red configuration See Figure 1 on page 4 Construction Housing ABS polycarbonate Lightpipes Acrylic Access Cap Polyester Operating Temperature 40 C to 65 C 40 F to 149 F Environmental Rating IEC IP67 Connections Integral 5 wire 2 m 6 5 ft cable or M12 Euro style QD fitting QD models require a mating cordset Certifications 3 1 Beam Patterns Typical Beam Pattern with BRTR CC20E Radar Target Ra...

Page 7: ...3 2 Dimensions All measurements are listed in millimeters inches unless noted otherwise Placeholder R GAGE Q130RA AF Sensor www bannerengineering com Tel 1 763 544 3164 7 D R A F T ...

Page 8: ...ndow which will repeat every 6 1 mm of distance between the sensor and the window The positions of maximum reflection from the window repeat between the minimums and decrease in effect until the window is approximately 150 mm 5 9 in away Consult the factory for pre tested window materials which can be used at any distance without issue Additionally the face of the window should be protected from f...

Page 9: ...5 2 Brackets and Enclosures SMBQ240SS1 Sensor mounting plate and pivoting bracket Provides 20 of tilt in one axis for enhanced sensor alignment 12 gauge stainless steel Sensor can mount on bracket horizontally or vertically SMBQ240SS2 Add on accessory to be used in conjunction with SMBQ240SS1 Provides 20 of tilt in second axis for maximum control of sensor alignment 12 gauge stainless steel SMBWSQ...

Page 10: ...UENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by B...