Specifications

Supply Voltage and Current

10 to 30V dc (10% max. ripple at 10% duty cycle) at 35
mA max current, exclusive of load

Sensing Beam

Visible red LED, 650 nm

Laser Classification

Class 1

Beam Size at Aperture

Approx. 3 mm

Supply Protection Circuitry

Protected against reverse polarity, over voltage, and
transient voltages

Delay at Power-Up

1 second max.; outputs do not conduct during this time

Output Configuration

Solid-state bipolar (SPDT): 1 current sourcing (PNP)
and 1 current sinking (NPN)
Rating: 150 mA maximum load
Off-state leakage current: < 10 µA at 30V dc
ON-state saturation voltage:

• NPN: less than 1.0V at 150 mA load
• PNP: less than 2.0V at 150 mA load

Output Protection Circuitry

Protected against output short-circuit, continuous over-
load, transient over-voltages, and false pulse on pow-
er-up

Output Response

500 microseconds

Repeatability

70 microseconds

Adjustments

2 push buttons and remote wire

• Easy push-button configuration
• Manually adjust (+/-) thresholds (push buttons only)
• LO/DO and OFF-delay configuration options
• Push-button lockout (from remote wire only)

Factory Defaults:

• No Delay
• Dark Operate
• Push buttons enabled

Indicators

Output conducting
8-Segment Red Bargraph
SETUP mode:
• Flashes Red when delay is selected
• Flashes Red when Dark Operate is selected
• Flashes Red when Light Operate is selected
RUN mode:

Model QS30LLP

Model QS30LLPC

LED 8: >6X

LED 8: >2X

LED 7: 5-6X

LED 7: 1.5-2X

LED 6: 4-5X

LED 6: 1-1.5X

LED 5: 3-4X

LED 5: 0.8X

LED 4: 2-3X

LED 4: 0.6X

LED 3: 1-2X

LED 3: 0.4X

LED 2: 0.5-1X

LED 2: 0.2X

LED 1: 0-0.5X

LED 1: 0X

Sensor calibration failure:

Construction
Environmental Rating

IEC IP67; NEMA 6

Connections

5-conductor 2 m (6.5 ft) PVC cable, 9 m (30 ft) PVC ca-
ble, or 5-pin integral Euro-style quick-disconnect fitting

Operating Conditions

Temp: –10° to +50° C (+14° to 122° F)
Relative Humidity: 90% at 50° C (non-condensing)

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method
201A (Vibration: 10 to 60Hz max. double amplitude
0.06 in, maximum acceleration 10G). Also meets IEC
947-5-2 requirements: 30G, 11 ms duration, half sine
wave.

Certifications

 

 

WORLD-BEAM QS30 LLP and LLPC

8

www.bannerengineering.com - tel: 763-544-3164

P/N 112355 Rev. C

Summary of Contents for QS30LLPQ

Page 1: ...objects Models Model Range and Use Spot Size at Fo cus Cable Supply Output Type QS30LLP 0 2 to 18 m 0 67 ft to 60 ft Maximum Excess Gain SET for Long Range Applications Approx 4 mm at 10 m 0 16 in at...

Page 2: ...are larger than the beam See Maximum Excess Gain SET Model QS30LLP on page 3 for more information MODEL QS30LLPC Q is configured using the Low Contrast SET procedure It is useful for small object det...

Page 3: ...ht saturated signal Output OFF Output ON Location of switchpoint adjusted via Manual Adjust Factory set Threshold Figure 3 Maximum Excess Gain SET Dark Oper ate shown Manual Adjust Maximum Excess Gain...

Page 4: ...Push Button Remote 0 04 seconds T 0 8 seconds Indicators 1 1 3 3 4 4 5 5 6 6 7 7 8 8 2 2 LO LO DO DO GAIN WORLD BEAM QS30 LLP and LLPC 4 www bannerengineering com tel 763 544 3164 P N 112355 Rev C...

Page 5: ...raph LEDs move to reflect the increase or decrease in ex cess gain LEDs 7 and 8 flash when maximum gain is achieved LEDs 1 and 2 flash when minimum gain is achieved If the target object does not cause...

Page 6: ...LO DO GAIN SETUP status indicators Figure 5 SETUP Mode Push Button 0 04 seconds T 0 8 seconds Result Access SETUP Mode Press and hold both push but tons 2 seconds Green Power LED turns OFF GAIN Selec...

Page 7: ...is forgiving just as it is with a conventional retroreflective sensor Effective Beam Size Unlike conventional retroreflective sensors the retroreflective laser has the ability to sense relatively sma...

Page 8: ...nly LO DO and OFF delay configuration options Push button lockout from remote wire only Factory Defaults No Delay Dark Operate Push buttons enabled Indicators Output conducting 8 Segment Red Bargraph...

Page 9: ...t permit a person to stare at the laser Do not point the laser at a person s eye at close range Mount open laser beam paths either above or below eye level where practical Terminate the beam emitted b...