background image

 

July 25, 2023

page 

16

Q5X with Dual Discrete Outputs and IO-Link Quick Start Guide

Dual Mode Reference Surface Considerations

Optimize reliable detection by applying these principles when selecting your reference surface, positioning your sensor relative to the refer­
ence surface, and presenting your target. 

The robust detection capabilities of the 

Q5X

 allows successful detection even under non­ideal conditions in many cases. Typical reference 

surfaces are metal machine frames, conveyor side rails, or mounted plastic targets. Contact Banner Engineering if you require assistance 

setting up a stable reference surface in your application. 

For detailed instructions for detecting clear or transparent objects, refer to the Instruction Manual, p/n 

208794

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of ship­

ment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the 
factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the 

improper application or installation of the Banner product. 

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUD­

ING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER 
ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.

 

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement.  IN NO EVENT SHALL BAN­

NER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, 
LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT 
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, 
TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

 

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or lia­
bilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installa­

tion of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes 

will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the prod­

uct warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications 

or update documentation at any time. Specifications and product information in English supersede that which is provided in any other lan­
guage. For the most recent version of any documentation, refer to: 

www.bannerengineering.com

For patent information, see 

www.bannerengineering.com/patents

Document title: Q5X Laser Measurement Sensor with Dual Discrete Outputs and IO­Link Quick Start Guide
Part number: 208795
Revision: H
Original Instructions
© Banner Engineering Corp. All rights reserved.

208795



 Select a reference surface with these characteristics where possible:

Matte or diffuse surface finish 
Fixed surface with no vibration 
Dry surface with no build­up of oil, water, or dust 

1. 

Position the reference surface between 200 mm (20 cm) and the maximum sensing range. 

2. 

 Position the target to be detected as close to the sensor as possible, and as far away from the reference surface as possible. 

3. 

 Angle the sensing beam relative to the target and relative to the reference surface 10 degrees or more. 

4. 

© Banner Engineering Corp.

Summary of Contents for Q5X

Page 1: ...icators The display is a 4 digit 7 segment LED Run mode is the primary view displayed For 2 pt BGS FGS and DYN TEACH modes the display shows the current distance to the target in centimeters For Dual...

Page 2: ...adiation exposure Do not attempt to disassemble this sensor for repair A defective unit must be returned to the manufacturer CAUTION Never stare directly into the sensor lens Laser light can damage yo...

Page 3: ...1 2014 as described in Laser Notice No 56 dated May 8 2019 Output 1 0 mW Laser wavelength 640 to 670 nm Pulse Duration for 5 m Models 20 s to 2 ms Pulse Duration for 5 m Models 3 s Installation Senso...

Page 4: ...1 bu 3 wh 2 10 30 V DC CH1 CH2 Load Load Channel 2 as Remote Input bk 4 bn 1 bu 3 wh 2 10 30 V DC CH1 CH2 Load Remote Input 1 4 3 2 NOTE Open lead wires must be connected to a terminal block NOTE The...

Page 5: ...water oil etc may create stray light that may degrade the peak performance of the sensor Blow the window clear using filtered compressed air then clean as necessary using only water and a lint free c...

Page 6: ...SS 9 2 m 30 2 ft M12 x 1 14 5 5 9 14 5 L1 47 4 47 4 M12 x 1 1 Brown 2 White 3 Blue 4 Black 5 Gray 5 Pin Threaded M12 Cordsets with Shield Single Ended Model Length Style Dimensions Pinout Female MQDEC...

Page 7: ...Setup mode and the sensor menu from Run mode by pressing and holding MODE for longer than 2 seconds Use and to navigate through the menu Press SELECT to select a menu option and access the submenus Us...

Page 8: ...July 25 2023 page 8 Q5X with Dual Discrete Outputs and IO Link Quick Start Guide Sensor Menu Map Channel 1 Banner Engineering Corp...

Page 9: ...Q5X with Dual Discrete Outputs and IO Link Quick Start Guide July 25 2023 page 9 Sensor Menu Map Channel 2 Banner Engineering Corp...

Page 10: ...ght ref erence point is a combination of the measured distance and returned signal intensity from the reference target Manual adjustment does not move the taught reference point but pressing increases...

Page 11: ...MIL STD 202G Method 201A Vibration 10 Hz to 55 Hz 0 06 inch 1 52 mm double amplitude 2 hours each along X Y and Z axes with device operating Operating Conditions 10 C to 50 C 14 F to 122 F 35 to 95 re...

Page 12: ...mm at 500 mm at 1000 mm at 2000 mm at 3000 mm 200 0 25 6 3 200 0 25 6 3 920 400 100 25 12 1600 700 200 50 25 3200 1400 400 100 50 Standard excess gain is available in 15 25 and 50 ms re sponse speeds...

Page 13: ...nerengineering com Supply Wiring AWG Required Overcurrent Protection A Supply Wiring AWG Required Overcurrent Protection A 20 5 0 26 1 0 22 3 0 28 0 8 24 1 0 30 0 5 FCC Part 15 Class A This equipment...

Page 14: ...bject separation distance 90 to 6 reflectance for the 2000 mm models Switch Point Distance Background X Y Typical performance curves for the 2000 mm models Minimum Separation Target to Background mm D...

Page 15: ...80 100 6 black 90 white 90 white 90 white Repeatability for 50 ms Response Time Repeatability 50 ms 0 1000 2000 3000 4000 5000 0 Dimension X 2 4 6 8 10 12 14 1 Repeatability in mm inch 6 black 18 Gray...

Page 16: ...LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STA...

Reviews: