1 Product 

Description

Laser Expert

 

diffuse

 sensor with bipolar (1 PNP & 1 NPN) output. Patent pending.

• Solves challenging 

part-detection

 

applications

 with small contrast 

differences

• High-speed part 

detection

 as fast as 250 µs, capturing up to 2,000 events per

second

• Some models with background suppression allow reliable contrast 

detection

with changing background 

conditions

• Angled three-digit display is easily viewed from 

multiple

 vantage points

• Display provides clear user feedback for easy setup, and bright output

indicator provides high visibility of sensor 

operation

Intuitive

 setup 

utilizing

 two 

tactile

 

buttons

 located below the display

• Rugged nickel-plated zinc, laser-marked housing suitable for use even in

environments where 

cutting

 

fluids

 and oils might be present

• Robust immunity to 

fluorescent

 light interference

WARNING: Not To Be Used for Personnel 

Protection

Never use this device as a sensing device for personnel 

protection.

 Doing so could lead to serious injury or death.

This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety

applications.

 A sensor failure or 

malfunction

 can cause either an energized or de-energized sensor output

condition.

1.1 Models

Model

Contrast Sensing Range

Background Suppression

Distance

Output Type

Connection

Q3XTBLD-Q8

0 to 300 mm (11.81 in)

Not Applicable

Bipolar: 1 NPN, 1 PNP

5-pin M12 Euro-style integral

connector

Q3XTBLD50-Q8

0 to 50 mm (1.97 in)

60 mm (2.36 in)

Q3XTBLD100-Q8

0 to 100 mm (3.94 in)

120 mm (4.72 in)

Q3XTBLD150-Q8

0 to 150 mm (5.91 in)

190 mm (7.48 in)

Q3XTBLD200-Q8

0 to 200 mm (7.87 in)

280 mm (11.02 in)

1.2 Overview

The Q3X Sensor is an Expert

 laser 

diffuse

 contrast sensor for low contrast 

detection

 

application.

 Some models of the Q3X are able to

ignore targets beyond a factory-set background suppression distance. This 

innovative

 

combination

 of low contrast 

diffuse

 sensing of

targets while ignoring objects beyond the region of interest eliminates the biggest problem of 

diffuse

 mode sensing, namely changing

background 

conditions

 

affecting

 the contrast 

detection.

The normal sensor state is Run mode. From Run mode, the switch point value can be changed and the selected TEACH method can be

performed. The secondary sensor state is Setup mode. From Setup mode, the TEACH mode can be selected, all standard 

operating

parameters can be adjusted, and a factory reset can be done.

1.3 Features

1

3

2

Figure 1. Sensor Features

1. Output Indicator (Amber)

2. Display

3.

Buttons

 

 

Q3X Laser Contrast Sensor

 

www.bannerengineering.com - Tel: 763.544.3164

3

Summary of Contents for Q3XTBLD150-Q8

Page 1: ...Q3X Laser Contrast Sensor Instruction Manual Original Instructions 181485 Rev E 12 July 2017 Banner Engineering Corp All rights reserved 181485...

Page 2: ...Cut Off Operation 10 3 1 9 Display View 11 3 1 10 Exit the Top Menu 11 3 1 11 Reset to Factory Defaults 11 3 2 Manual Adjustments 12 3 3 Remote Input 12 3 3 1 Select the TEACH mode using the Remote I...

Page 3: ...zed or de energized sensor output condition 1 1 Models Model Contrast Sensing Range Background Suppression Distance Output Type Connection Q3XTBLD Q8 0 to 300 mm 11 81 in Not Applicable Bipolar 1 NPN...

Page 4: ...y default the sensor treats a target in the background as a dark signal and honors the LO DO selection A displayed value of indicates no light received or a loss of signal In Window Set teach mode the...

Page 5: ...those specified herein may result in hazardous radiation exposure Do not attempt to disassemble this sensor for repair A defective unit must be returned to the manufacturer CAUTION Never stare directl...

Page 6: ...ensing range and that any background objects are positioned beyond the background suppression distance Figure 4 Optimal Orientation of Target to Sensor 2 3 Sensor to Background Position Target Backgro...

Page 7: ...n is off disabled 2 6 Cleaning and Maintenance Handle the sensor with care during installation and operation Sensor windows soiled by fingerprints dust water oil etc may create stray light that may de...

Page 8: ...ously or press and hold and simultaneously for longer than 2 seconds to return to Run mode from anywhere in the top menu 3 1 1 Output Operation Use this menu to select the output operation mode The de...

Page 9: ...or direct line of sight crosstalk Enabled 3 1 5 Output Timing Delays Use this menu to select the output timing delay to be set Only one delay type can be used at a time The default is no delay No dela...

Page 10: ...on The default is off Ignore all pulses Laser off when pulled low Remote TEACH input Master sync line output for two sensor cross talk avoidance Slave sync line output for two sensor cross talk avoida...

Page 11: ...avigate to and press TEACH and MODE together to exit the top menu and return to Run mode Setup mode can also be exited by pressing and holding and simultaneously for longer than 2 seconds from anywher...

Page 12: ...manual The length of the individual programming pulses is equal to the value T 0 04 seconds T 0 8 seconds 1x 2x Teach Selection Starts selected Teach same function as pressing Teach Button for 2 sec 1...

Page 13: ...modified default The sensor is locked and no changes can be made The switch point value can be changed by teaching or manual adjustment but no sensor settings can be changed through the menu When in m...

Page 14: ...Low 20 to 40 Good 40 to 60 Robust 60 Excellent 3 5 2 Two Point Static TEACH Two point TEACH sets a single switching threshold The sensor centers the switch point between two taught conditions with th...

Page 15: ...is between the minimum and maximum signal level limits Sets the threshold between the two taught conditions The current NSS displays Both taught conditions are darker than the minimum signal value li...

Page 16: ...ernately on the display The DYN indicator flashes Remote Input No action required n a 3 Teach the sensor Method Action Result Push Button Press TEACH to teach the target The sensor begins sampling tar...

Page 17: ...percentage Use the menu to set the window offset percentage The default is 20 Darkest no signal Most Light saturated signal Single taught point Sensing window size adjusted by Manual Adjust Output OF...

Page 18: ...NSS displays 3 5 5 Light Set Light set sets a switching threshold a user selectable percent offset below the presented condition Use the menu to set the offset percentage The default is 20 Output OFF...

Page 19: ...ion is brighter than the maximum signal value limit Sets the threshold at the maximum level minus the value The current NSS displays 3 5 6 Dark Set Dark set sets a switching threshold a user selectabl...

Page 20: ...splays The taught condition is darker than the minimum signal value limit Sets the threshold at the minimum level Sets the sensor at the maximum detection condition briefly displays and then the curre...

Page 21: ...t Setup Reset to Factory Defaults Available when set to 1Sh Available when set to on ms default setting BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH Light Operate Dark Operate Dark Set min 1...

Page 22: ...ow State 2 0 V at 1 mA max Output Configuration Bipolar 1 PNP 1 NPN output Output Rating Discrete Output 100 mA maximum protected against continuous overload and short circuit Off state Leakage Curren...

Page 23: ...Equipment 3TJJ Class 2 power 4 1 Performance Curves Performance is based on a 90 reflectance white test card Note For high sensitivity the excess gain increases by a factor of 1 5 For low sensitivity...

Page 24: ...will be 65 of the sensing cut off distance of a 90 reflective white card For 200 mm models the sensing cut off distance for a 6 reflective black card will be 50 of the sensing cut off distance of a 90...

Page 25: ...adjustment or after a TEACH Calibration set Cutoff A target is detected in the background models with background suppression only Output timing delays Dark operate Dark set Display read Delay timer D...

Page 26: ...ach function or Set used in the TEACH procedures Standard sensitivity Slave Response speed Stop Teach process selection Top The sensor is at maximum gain during a manual adjust or after a TEACH Window...

Page 27: ...ons reposition the sensor or the target Table 12 Error Codes Code Description Resolution Output short circuit Check the wiring for an electrical short circuit Laser fault Contact Banner Engineering to...

Page 28: ...0 ft MQDC1 506RA 1 83 m 6 ft Right Angle 32 Typ 1 26 30 Typ 1 18 14 5 0 57 M12 x 1 MQDC1 515RA 4 57 m 15 ft MQDC1 530RA 9 14 m 30 ft 5 Pin Threaded M12 Euro Style Cordsets Washdown Stainless Steel Mod...

Page 29: ...and pan movement for precision adjustment Easy sensor mounting to extruded rail T slots Metric and inch size bolts available 18 mm sensor mounting hole 66 69 A B Hole size B 18 1 Model Bolt Thread A S...

Page 30: ...s No 103 Col Valle Oriente C P 66269 San Pedro Garza Garcia Nuevo Leon Mexico Phone 52 81 8363 2714 or 01 800 BANNERE toll free Website www bannerengineering com mx Email mexico bannerengineering com...

Page 31: ...OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STR...

Reviews: