A displayed value of 

 indicates no light received or a loss of signal.

In Window Set teach mode, the value 100 represents the taught signal strength. The displayed value is the percentage of

the received light divided by the taught signal strength. The output switches at displayed values above and below 100 as

determined by the user-selected window offset percentage.

Output Indicator

On—Outputs conducting (closed)

Off—Outputs not conducting (open)

Stability Indicator (STB)

On—Stable light signal received

Flashing—Light intensity is within the switching threshold hysteresis band

Off—No light signal received

Active TEACH Indicators (DYN and WND)

DYN and WND off—Two-Point Static , Light Set, or Dark Set TEACH mode selected (Two-Point Static TEACH is the

default).

DYN and/or WND flashing—The sensor is in TEACH mode.

DYN on—Dynamic TEACH mode selected

WND on—Symmetric Window thresholds are active. The switch points are above and below 100 by the offset

percentage

Buttons

Use the sensor buttons (-)(MODE) and (+)(TEACH) to program the sensor.

See 

Sensor Programming 

on page 4 for programming instructions.

(-)(MODE)

Decrease gain: press and release (-)(MODE), then press and hold (-)(MODE) to rapidly decrease gain

Enter Setup mode: press and hold (-)(MODE) for longer than 2 seconds

Navigate the sensor menu: press (-)(MODE)

Change setting values: press and hold (-)(MODE) to decrease numeric values

(+)(TEACH)

Increase gain: press and release (+)(TEACH), then press and hold (+)(TEACH) to rapidly increase gain

Start the currently selected TEACH mode: press and hold (+)(TEACH) for longer than 2 seconds (Two-Point Static

TEACH is the default)

Navigate the sensor menu: press (+)(TEACH)

Change setting values: press and hold (+)(TEACH) to increase numeric values

(-)(MODE) and (+)(TEACH)

Select menu items in Setup mode: press (-)(MODE) and (+)(TEACH) simultaneously

Select and save a parameter and return to Run mode: press (-)(MODE) and (+)(TEACH) simultaneously for

longer than 2 seconds

When navigating the menu systems, the menu items loop.

 

 

Q3X Laser Contrast Sensor

2

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 181486 Rev. D

Summary of Contents for Q3XTBLD-Q8

Page 1: ... Amber WND Symmetric window thresholds are active Amber In Run mode the 3 digit 7 segment display provides real time information about signal strength for all models and target position for models with a fixed background suppression distance The numeric value of 0 to 990 represent the amount of the received light divided by the threshold and represents the excess gain of the sensing event expresse...

Page 2: ...are above and below 100 by the offset percentage Buttons Use the sensor buttons MODE and TEACH to program the sensor See Sensor Programming on page 4 for programming instructions MODE Decrease gain press and release MODE then press and hold MODE to rapidly decrease gain Enter Setup mode press and hold MODE for longer than 2 seconds Navigate the sensor menu press MODE Change setting values press an...

Page 3: ...el together Figure 3 Safety Label Installation Sensor Orientation Correct sensor to target orientation is important to ensure proper sensing To ensure reliable detection orient the sensor as shown in relation to the target to be detected For models with background suppression make sure the intended target is inside of the contrast sensing range and that any background objects are positioned beyond...

Page 4: ...idental programming changes See the Instruction Manual for more information Setup Mode 1 Access Setup mode from Run mode by pressing and holding MODE for longer than 2 seconds 2 Use or to navigate through the top menu 3 Select the desired submenu by pressing and simultaneously 4 Press or to view the available options in the submenu 5 Select a submenu option Press and simultaneously to select and s...

Page 5: ... sensor s gain or press and hold or to rapidly decrease or increase gain After 1 second the normalized signal strength flashes rapidly the new setting is accepted and the sensor returns to Run mode Locking and Unlocking the Sensor Buttons Use the lock and unlock feature to prevent unauthorized or accidental programming changes To lock or unlock the sensor using the buttons press and hold and immed...

Page 6: ...Figure 11 Beam Pattern NOTE For high sensitivity the excess gain increases by a factor of 1 5 For low sensitivity the excess gain decreases by a factor of 0 75 Specifications Sensing Beam Visible red Class 2 laser 655 nm Supply Voltage Vcc 10 to 30 V dc Power and Current exclusive of load Supply Power 675 mW Current consumption 28 mA at 24 V dc Supply Protection Circuitry Protected against reverse...

Page 7: ...by qualified personnel in accordance with local and national electrical codes and regulations Supply Wiring Required Overcurren t Protection 20 5 0 Amps 22 3 0 Amps 24 2 0 Amps 26 1 0 Amps 28 0 8 Amps 30 0 5 Amps Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Bann...

Page 8: ...d Exit Setup Reset to Factory Defaults Available when set to 1Sh Available when set to on ms default setting BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH Light Operate Dark Operate Dark Set min 10 20 30 40 50 Window Light Set options 20 is default for Light Set and Window min 25 50 100 200 Dark Set options 50 is default for Dark Set set Response Speed to 250 microseconds set Response Spe...

Reviews: