![Banner LE550DC1 Instruction Manual Download Page 15](http://html1.mh-extra.com/html/banner/le550dc1/le550dc1_instruction-manual_3834215015.webp)
Action
Result
Single-pulse the remote input.
T
"TchSPt2 Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
of the display, flashes, and the sensor
returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step
2, and "RMT TCH" displays.
3.5.2 Midpoint TEACH
Output OFF
0 mm
(500 mm)
(700 mm)
(600 mm)
1000 mm
SP1
SP2
Midpoint
Output ON
Figure 16. Window and Midpoint Example
The Midpoint TEACH uses both the window size and the
TEACH midpoint to determine the actual measurement
window. For example, a window of 200 mm with a midpoint
of 600 mm places the measurement window from 500 mm to
700 mm.
To use Midpoint TEACH:
1. Set the window size using
on page 15.
2. Set the measurement window using
on page 16.
The Midpoint TEACH options for D1_OUT and D2_OUT are
independent settings.
Window Size
The WndSize option sets the window size that the Midpoint TEACH uses to set the setpoint one and setpoint two
thresholds.
The Midpoint TEACH will fail if one of the setpoints is beyond the measurement range. The bigger the window size, the
smaller the acceptable TEACH range.
LE250 Laser Sensor
LE550 Laser Sensor
Window Size Minimum
1 mm
10 mm
Window Size Maximum
250 mm
800 mm
Range
100 mm to 400 mm
100 mm to 1000 mm
Default Window Size
50 mm
300 mm
Navigate: MENU > Dx_OUT > TchMid > WndSize
Remote Input: Available
1. Access the setup mode.
Method
Action
Result
Push Button
Navigate: MENU > Dx_OUT > TchMid > WndSize .
"WndSize" and the current window
size value display.
Remote Input
a. Double-pulse the remote input to enter
setup mode.
b. Three-pulse the remote input to enter
window size mode.
T
T
T
T
T
T
T
T
a. "REMOTE SETUP" displays.
b. "WndSize" and the current value
display.
L-GAGE
®
LE250/550 Dual Discrete Laser Gauging Sensors
www.bannerengineering.com - Tel: 763.544.3164
15