Banner L-GAGE LE250 IO-Link Quick Start Manual Download Page 6

OffDly  0 ms
Off1Sho  0 ms
OnDly  0 ms
On1Sho  0 ms

TchSPt1 100 mm
TchSPt2 1000 mm

Tch2Pt TchSPt2

Tch2Pt TchSPt1

WndSize 300 mm
TchMdPt 500 mm

TchMid TchMdPt

TchMid WndSize

Mode Health

Mode Alarm

Timer On1Sho

Timer OffDly

Polarity NPN

Polarity PNP

Mode SPt
Mode SPt
Mode Wnd
Mode Wnd

Timer Off1Sho
Timer OnDly

AdjSPt2 1000 mm

AdjSPt1 100 mm

D2_OUT Tch2Pt

D2_OUT TchMid

D2_OUT Mode

D2_OUT Polarity

D2_OUT Timer

D2_OUT AdjSPt1

D2_OUT AdjSPt2

Run

Mode

Enter Quick Menu Loop

(see Quick Menu diagram)

MENU D1_OUT

MENU D2_OUT

MENU INPUT

LE Series User Interface

Enter

Top Menu

(Continued on right side)

(Continued from left)

Top Menu

MENU MEASURE

MENU DISPLAY

MENU INFO

MENU RESET

Sub Menus

Top Menu

Sub Menus

or

or

Go Back to Parent Menu

Select Menu Item

Press to Save Setting

Press and Hold to Go Back

to Run Mode

OffDly  0 ms
Off1Sho  0 ms
OnDly  0 ms
On1Sho  0 ms

TchSPt1 100 mm
TchSPt2 1000 mm

Tch2Pt TchSPt2

Tch2Pt TchSPt1

WndSize 300 mm
TchMdPt 500 mm

TchMid TchMdPt

TchMid WndSize

Mode Health

Mode Alarm

Timer On1Sho

Timer OffDly

Polarity NPN

Polarity PNP

Mode SPt
Mode SPt
Mode Wnd
Mode Wnd

Active High

Active Low

Type LasrEnbl

Type Teach

Type SyncMstr
Type SyncSlve
Type Disabled

Speed Standard

Speed Fast

Speed Medium
Speed Slow

Timer Off1Sho
Timer OnDly

AdjSPt2 1000 mm

AdjSPt1 100 mm

Sleep 1min

Sleep Disabled

Units in

Units mm

View Invert

View Normal

Sleep 5min
Sleep 15min
Sleep 60min

Version 1.0.0

Model LE550D

P/N 94198

S/N F..S..P..D..

D1_OUT Tch2Pt

D1_OUT TchMid

D1_OUT Mode

D1_OUT Polarity

D1_OUT Timer

INPUT Active

INPUT Type

MEASURE Speed

D1_OUT AdjSPt1

D1_OUT AdjSPt2

DISPLAY Sleep

DISPLAY Units

DISPLAY View

INFO Version

INFO Model

INFO P/N

INFO S/N

RESET No

RESET Yes

Default Setting

SPtRef Object
SPtRef Backgrnd

D1_OUT SPtRef

SPtRef Object
SPtRef Backgrnd

D2_OUT SPtRef

(in SPt mode only)

(in SPt mode only)

Figure 13. LE550 Sensor Menu Map (Dual Discrete Models)

 

 

L-GAGE

®

 LE250/550 Dual Discrete Laser Sensors

6

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 185580 Rev. C

Summary of Contents for L-GAGE LE250 IO-Link

Page 1: ...ete Sensor Features Three LED indicators provide ongoing indication of the sensing status Power LED Indicator Solid Green Normal operation power On and laser On Flashing Green 1 Hz Power On and laser Off laser enable mode Discrete Output LED Indicators Solid Amber Discrete Output is On Off Discrete Output is Off Laser Description and Safety Information CAUTION Use of controls or adjustments or per...

Page 2: ...PLIES WITH IEC 60825 1 2007 CLASS 1 LASER PRODUCT Output Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice N o 50 dated June 24 200 7 Figure 3 FDA CDRH warning label Class 1 Laser wavelength 650 nm Output 0 22 mW Pulse Duration 150 µs to 900 µs Sensor Installation NOTE Handle the sensor with care during installation and operation Sensor windows soiled by finge...

Page 3: ...d the bracket in the aligned position Wiring Diagrams 3 1 4 5 shield 2 12 30 V dc D1_Out D2_Out Input Load NPN PNP User configurable PNP NPN setting Load or Figure 9 Dual Discrete Models Key 2 3 4 1 5 1 Brown 2 White 3 Blue 4 Black 5 Gray Display Figure 10 LE550 Display in Run Mode The display is a 2 line 8 character LCD The main screen is the Run mode screen which shows the real time distance mea...

Page 4: ...nges In the Sensor Menu a return arrow in the upper left corner of the display indicates that pressing Escape returns to the parent menu Press and hold Escape for 2 seconds to return to Run mode from any menu or remote teach Sensor Programming Program the sensor using the buttons on the sensor or the remote input limited programming options From Run mode use the buttons to access the Quick Menu an...

Page 5: ...ress Enter to save the new value and return to the Quick Menu Quick Menu D1 SPt1 value Run Mode D1 SPt2 value D2 SPt1 value D2 SPt2 value Spt2 not available unless in Window Mode set value with or Save setting and return to Quick Menu Cancel and return to Quick Menu access Sensor Menu Top Menu Figure 12 Quick Menu Map Window Mode Sensor Menu MENU Access the Sensor Menu by pressing Enter from Run m...

Page 6: ...Pt TchSPt2 Tch2Pt TchSPt1 WndSize 300 mm TchMdPt 500 mm TchMid TchMdPt TchMid WndSize Mode Health Mode Alarm Timer On1Sho Timer OffDly Polarity NPN Polarity PNP Mode SPt Mode SPt Mode Wnd Mode Wnd Active High Active Low Type LasrEnbl Type Teach Type SyncMstr Type SyncSlve Type Disabled Speed Standard Speed Fast Speed Medium Speed Slow Timer Off1Sho Timer OnDly AdjSPt2 1000 mm AdjSPt1 100 mm Sleep ...

Page 7: ...x Low State 1 3 V at 1 6 mA max Measurement Output Rate Class 2 Laser Models 1 ms Class 1 Laser Models Fast 1 ms Class 1 Laser Models Std Medium Slow 2 ms Minimum Window Size LE250 1 mm 0 039 inches LE550 10 mm 0 39 inches Boresighting LE250 4 mm radius at 400 mm LE550 1 cm radius at 1 m Maximum Torque 2 N m 17 7 in lbs Indicators Power LED Indicator Solid Green Normal operation power On and laser...

Page 8: ...nt protection may be provided with external fusing or via Current Limiting Class 2 Power Supply Supply wiring leads 24 AWG shall not be spliced For additional product support go to http www bannerengineering com Supply Wiring AWG Required Overcurrent Protection Amps 20 5 0 22 3 0 24 2 0 26 1 0 28 0 8 30 0 5 Performance Curves LE250 Dual Discrete Models LE550 Dual Discrete Models 0 6 0 5 0 4 0 3 0 ...

Page 9: ...LUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP B...

Reviews: