background image

K30 Pro Optical Sensor Quick Start Guide

June 22, 2023

page 

3

Continued from page 2

 

Red 

Yellow 

Green 

Cyan 

Blue 

Magenta 

White 

Input 3 

 

 

 

Configuring a Sensor

The 

K30 Pro Optical Sensor

 has three Teach modes. These modes are indicated with a Teach Status color. 

The Signal Level color flashes in between the Teach Status color. The color of the Signal Level depends on the signal strength of the target:

Green: Best signal, accepts Teach 
Yellow: Acceptable signal, can accept Teach 
Red: Poor signal, rejects Teach 

Remote Input

Use the remote input to program the sensor remotely. 

The remote input provides limited programming options and is Active High in PNP mode (V+ to brown wire), or Active Low in NPN mode (V+ 
to blue wire). For Active High, pulse the gray or yellow input wire to V+ (10 V DC to 30 V DC). For Active Low, pulse the gray or yellow input 

wire to ground (0 V DC). 

The remote input wire is enabled by default. Pulse the remote input wire 7 times or use the 

Banner Pro Editor

 software to enable or disable 

the feature. When the remote input feature is enabled, pulse the remote input according to the diagram and the instructions provided in this 

manual. Remote teach can also be performed using the button on the Pro Converter Cable. 

The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds. 

Exit remote programming modes by cycling power or by waiting for 30 seconds. 

NOTE: 

 If a factory reset is performed through the 

Banner Pro Editor

 Software, the remote input wire becomes enabled 

(factory default setting). If the sensor is returned to factory defaults by using the remote input wire, the input wire re­
mains enabled and the rest of the settings are restored to factory defaults. 

Remote Teach 

Use the following procedure to teach the Set Point. 

 Pulse the remote input: 

3x ­ Object Teach: The indicator alternates between a blue Teach Status color and the Signal Level color. 

4x ­ Background Teach: The indicator alternates between a magenta Teach Status color and the Signal Level color. 

5x ­ Window Teach: The indicator alternates between a cyan Teach Status color and the Signal Level color. 

1. 

Present the Set Point. 

2. 

Teach the Set Point. 

Action 

Result 

 Single pulse the remote input. 

T

 

Teach Accepted

 

The indicator stops flashing and the device returns to operation. 

Teach Not Accepted

 

The Signal Level color turns red during the teach procedure, and then the 

indicator stops flashing. 

Retry teaching the set point. 

3. 

© Banner Engineering Corp.

Reviews: