Window Mode
Teach Status Color: Cyan
Window Mode centers the total Detection Area at the Set Point plus and minus the Offset Value (50 mm default). Configuring a window near the minimum and
maximum ranges shifts this window to ensure that it maintains this value. Use Window Mode when a change in state is desired within a specific narrow area, and not
when outside this area.
Five-pulse the remote input to enable Window Mode. Successfully entering Window Mode causes the device to alternate between the Teach Status color (Cyan) and
the Signal Level color.
Reset the Sensor to Factory Defaults
Reset the sensor to factory default settings using one of two methods.
NOTE
:
If a factory reset is performed through the Banner Pro Editor Software, the remote input wire becomes disabled (factory default setting). If the sensor is returned
to factory defaults by using the remote input wire, the input wire remains enabled and the rest of the settings are restored to factory defaults.
Reset Using the Banner Pro Editor Software
Go to
Sensor > Factory Reset
. The sensor indicators flash once, the sensor is reset back to the factory default settings, and a confirmation message displays.
Reset Using the Remote Input
Nine-pulse the remote input to reset the device to factory default settings. The device then flashes white on success.
Pulse the remote input once more to apply the factory defaults.
Factory Default Settings via Remote Teach Mode
Alternate Modes Available
The K30 Pro Optical Sensor has alternate modes available for use, which are configurable with Pro Editor.
Table 7:
Default Settings
Setting
Factory Default
Discrete Output and Remote Input
Bimodal
Remote Input Wire
Enabled
Offset
50 mm (2 in)
Operation Mode
Object Mode
D1
20 mm
D2
Model specific
NO/NC
Normally open
On Delay
0 ms
Off Delay
0 ms
Detection Area
Switch Point (D2)
Set Point
-50 mm
(Offset Value)
Detection Area
Set Point
Switch Point (D1)
Switch Point (D2)
-50 mm
(Offset Value)
+50 mm
(Offset Value)