B
ANNER
E
NGINEERING
C
ORP
.
February 7, 2023
K30 Pro Optical Sensor Instruction Manual
Instruction Manual
30 mm Programmable Multicolor RGB Optical Sensor and Indicator
WARNING
!
DO NOT USE THIS DEVICE FOR PERSONNEL PROTECTION
Using this device for personnel protection could result in serious injury or death.
•
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel
safety applications. A device failure or malfunction can cause either an energized (on) or de-energized (off)
output condition.
Models
Overview
The K30 Pro Optical Sensor is an adjustable field optical sensor that can detect a wide variety of materials and objects.
Configure the sensor using software or remote input wires to sense objects up to a specific distance, ignoring objects beyond this distance (background suppression),
or within a windowed range.
•
Programmable using Banner's Pro Editor software and Pro Converter Cable
•
Up to 7 colors in one device (14 colors using Pro Editor)
•
Devices are completely self-contained—no controller needed
•
Teachable modes with color feedback for ease of use
•
Touchless activation removes the need for physical force to activate
•
Rated IP65
•
10 V DC to 30 V DC operation
•
Resistant to ambient light, EMI, and RFI interference
•
Sensing and indication in one device
Model
D0 (mm)
Switch Point D1 (mm)
Switch Point D2 (mm)
K30PAF1000
0
20
1000
** Models with a quick disconnect
require a mating cordset
Family
K30
GRY3 = Programmable Multicolor
(3 Color, 5-Pin)
Color/Control
P = Pro
Q = 5-pin or 8-pin integral
M12 quick disconnect
depending on model **
Q
Connector
M = Momentary
Output
Function
Activation
Method
Output State
A = Normally Open
P
AF100
A
M
GRY3
Style
AF100 = 100 mm adjustable field*
AF1000 = 1000 mm adjustable field*
* Detection distance can be adjusted through
teach mode or Pro Editor
Max distance = 1000 mm.
GRY4 = Four State, Full Logic Multicolor
(3 Color, 5-Pin)
RGB7 = Programmable Multicolor
(7 Color, 8-Pin)
D0
Measurement
Reference Point
D1
D2
Detection Area
Reliable detection of a stationary
and moving object
Detection not
possible