WORD #
WORD NAME
DATA TYPE
303-320
Barcode-4 Data
32-bit 32-byte array
321
Barcode-5 Type
16-bit integer
322
Barcode-5 Length
16-bit integer
323-340
Barcode-5 Data
32-bit 32-byte array
341
Barcode-6 Type
16-bit integer
342
Barcode-6 Length
16-bit integer
343-360
Barcode-6 Data
32-bit 32-byte array
361
Barcode-7 Type
16-bit integer
362
Barcode-7 Length
16-bit integer
363-380
Barcode-7 Data
32-bit 32-byte array
381
Barcode-8 Type
16-bit integer
382
Barcode-8 Length
16-bit integer
383-400
Barcode-8 Data
32-bit 32-byte array
401
Barcode-9 Type
16-bit integer
402
Barcode-9 Length
16-bit integer
403-420
Barcode-9 Data
32-bit 32-byte array
421
Barcode-10 Type
16-bit integer
422
Barcode-10 Length
16-bit integer
423-440
Barcode-10 Data
32-bit 32-byte array
14.6.4 Input and Output Flags
The Input Bits are used to command execution of basic functions. The Output Bits are used to push single bit outputs from
the iVu BCR device to the PLC. The 32 bits of iVu BCR output can also be accessed using the bits of the first two Output
Registers (Input Bits ACK Register(word 0) and Output Bits Register (word1)).
Table 23: Inputs Bits Register
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Command
Set BCR
Mask
Set BCR
String
Gated
Trigger
Trigger
Teach
Latch
Product
Change
Table 24: Bit Position
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Command
ACK
Set BCR
Mask
ACK
Set BCR
String
ACK
Gated
Trigger
ACK
Trigger
ACK
Teach
Latch
ACK
Product
Change
ACK
Table 25: Output Bits Register
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Execution
Error
System
Error
Teach
Error
Missed
Trigger
Output 3
Output 2
Output 1
Ready
Latch
Read/No
Read
Pass/Fail
Ready
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767
129