Sensor positions 

threshold midway 

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Figure 4. Two-Point TEACH (Light Operate shown)

Reverse the Output ON and OFF conditions by using the LO/DO (Light Operate/ Dark Operate) selection through the

program interface for the dual output model.

Dynamic TEACH

Teaches on-the-fly

Establishes a single switching threshold

Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)

Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual

sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the

optimum level.

Sensor positions 

threshold midway 

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Figure 5. Dynamic TEACH (Light Operate shown)

Reverse the CH2 Output ON and OFF conditions by using the LO/DO (Light Operate/ Dark Operate) selection through the

program interface.

Window SET

Sets window thresholds that extend a programmable % offset above and below the presented condition

All other conditions (lighter or darker) cause the output to change state

Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust)

Recommended for applications where a product may not always appear in the same place, or when other signals

may appear

See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease the

window size)

A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and

below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside

the window, and the Output OFF conditions outside the window.

DF-G3 Long Range Expert

 Dual Display Fiber Amplifier with Analog Output

 

 

P/N 190340 Rev. B

www.bannerengineering.com - Tel: +1-763-544-3164

9

Summary of Contents for DF-G3 Long Range Expert

Page 1: ...pertinent industry standards and practices WARNING Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection Doing so could lead to serious injury or d...

Page 2: ...3 Pivot the DF G3 onto the DIN rail pressing until it snaps into place 2 Mount to the Accessory Bracket SA DIN BRACKET 1 Position the DF G3 in the SA DIN BRACKET 2 Insert the supplied M3 screws 3 Tigh...

Page 3: ...OTE If a thin fiber with less than 2 2 mm outer diameter is used install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Align the fibers to the end of...

Page 4: ...ert TEACH SET methods and Manual Adjust see Adjust Mode on page 7 CH1 CH2 Switch The CH1 CH2 switch selects which output s parameters can be accessed and changed in the interface of the display CH1 se...

Page 5: ...t how to perform TEACH SET methods and to program the sensor remotely see www bannerengineering com and search 190341 Run Mode Run mode allows the sensor to operate normally and prevents unintentional...

Page 6: ...to exit choice list without saving DISPLAY LOOP Return to Menu List PROGRAM MODE Mode Switch to PRG Click SET to enter choice list DISPLAY LOOP Click SET to enter choice list Click SET to enter choic...

Page 7: ...ick SET to enter choice list default setting setting specific Click SET to enter choice list DISPLAY LOOP or to set value Click SET or to set value Click SET or to set value Click SET or to set value...

Page 8: ...Point SET Defines the 5 V 12 mA midpoint of the analog output Analog midpoint can be adjusted by using the and rocker button Manual Adjust A single sensing condition is presented and the sensor posit...

Page 9: ...Lightest Taught Condition Position adjusted by Manual Adjust Figure 5 Dynamic TEACH Light Operate shown Reverse the CH2 Output ON and OFF conditions by using the LO DO Light Operate Dark Operate sele...

Page 10: ...he output either turns ON or OFF depending on the LO DO setting Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable offset below the presented condition Darkest no s...

Page 11: ...Current output models 10 V to 30 V dc Class 2 10 maximum ripple Power and Current Consumption exclusive of load Standard display mode 840 mW Current consumption 35 mA at 24 V dc ECO display mode 672...

Page 12: ...quick disconnect or 150 mm 6 in cable with a 5 pin M12 Euro style quick disconnect For Q3 or Q7 models either a 5 pin M8 Pico style or a 6 pin M8 Pico style mating cordset may be used Construction Bl...

Page 13: ...URPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN...

Reviews: