RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN mode allows

the sensor to operate normally and prevents unintentional programming changes via the +/SET/- button. PRG mode

allows the sensor to be programmed through the display driven programming menu (see Program Mode below).

ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust Mode below).

 

 

LO/DO Switch
The LO/DO switch is used to select Light Operate or Dark Operate mode. In Light Operate mode, the output is ON

when the sensing condition is above the threshold (for Window SET, the output is ON when the sensing condition is

inside the window). In Dark Operate mode, the output is ON when the sensing condition is below the threshold (for

Window SET, the output is ON when the sensing condition is outside the window).

 

 

+/SET/- Rocker Button
The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/right. The SET

position is engaged by clicking down the button while the rocker is in the middle position. All three button positions

are used during PRG mode to navigate the display driven programming menu. During ADJ mode, SET is used to

perform TEACH/SET methods and +/- are used to manually adjust the threshold(s). The rocker button is disabled

during RUN mode, except when using Window SET, see 

Window SET

 on page 6.

 

 

Red/Green Digital Displays
During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the threshold.

During PRG mode, both displays are used to navigate the display driven programming menu.

Output LED
The output LED provides a visible indication when the output is activated.

Operating Instructions

Remote Input/IO-Link

For more information about how to perform TEACH/SET methods, to program the sensor remotely, or to interface with the sensor

via IO-Link, see the DF-G1 Manual (P/N 161999).

Run Mode 

Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker button is

disabled during RUN mode, except when using Window SET.

 

 

DF-G1 Expert

 Dual Display Fiber Amplifier

4

www.bannerengineering.com - Tel: + 1 888 373 6767

P/N 161275 Rev. E

Summary of Contents for DF-G1 Expert

Page 1: ...ch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M...

Page 2: ...Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop 4 Move the fi...

Page 3: ...grams NPN Models Load 10 30V dc Remote Programming N O 1 3 4 2 PNP Models Load 10 30V dc Remote Programming N O 1 3 4 2 Key 1 Brown 2 White 3 Blue 4 Black IO Link Models PUSH PULL 18 30 V dc Load Load...

Page 4: ...engaged by clicking down the button while the rocker is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET...

Page 5: ...1234 Eco 123P diSP 1234 diSP 123P Eco 1234 Eco 123P display flips 180 1234 Gn 8 Fixed Gain Set To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a ch...

Page 6: ...on adjusted by Manual Adjust Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can be reversed by using the LO DO Light Operate Dark Operate switch Dynamic TEACH Teaches on...

Page 7: ...background with varying darker targets See Program Mode for programming the Offset Percent setting A single sensing condition is presented and the sensor positions a threshold a programmable offset be...

Page 8: ...Thresholds are ON the Green display will flash Percent Minimum Difference after TEACH The Two Point and Dynamic TEACH methods will flash a minimum difference on the displays after a PASS or FAIL Value...

Page 9: ...NPN or 1 current sourcing PNP output depending on model IO Link models 1 push pull and 1 PNP complementary outputs Repeatability High Speed 66 s Standard Long Range Extra Long Range 100 s Connections...

Page 10: ...Y OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the dis...

Reviews: