Method
Action
Result
Push Button
Click "+" to increase, or click "-" to decrease.
or
Display briefly flashes the threshold setpoint
value as it is being changed
OR
Display flashes"inc" or "dEc" as the window
size is adjusted
or
Remote Input7
Not available with remote programming
n/a
Sensor Setup
• Configures sensor display and operating parameters
• Changes are updated instantly
• Click Dynamic (+) or double-pulse remote line to select an option
• Click Static (-) or single-pulse remote line to advance
Push Button
Remote
0.04 seconds
≤
T
≤
0.8
seconds
Result
Access SETUP
Mode
Press and hold both buttons concurrently for
> 2 seconds.
Double-pulse the remote line.
T
T
T
Indicator Arrow Icon 1 ON Red
Select Light/
Dark Operate
Click Dynamic (+) to toggle between
selections.
Double-pulse remote line to
toggle between selections.
T
T
T
Light Operate
•
Display flashes
"lo"
•
L icon
Dark Operate
•
Display flashes
"do"
•
D icon
Click Static (-) to save selection and advance
to "OFF-Delay."
Single-pulse remote line to save
selection and advance to "OFF-
Delay."
T
Select OFF-
Delay Timing
Enable
Click Dynamic (+) to toggle between
selections.
Double-pulse remote line to
toggle between selections.
T
T
T
Off (No OFF-Delay)
•
"t 0"
•
Clock icon OFF
7 0.04 seconds
≤
T
≤
0.8 seconds
D10 Expert
™
- Analog and Discrete Outputs
10
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 65448 Rev. G