Quick Start Guide

Installing the BWA-BK-012 and -014 Bracket Assemblies

Required equipment, which is included in the BWA-BK-012 and BWA-

BK-014 bracket assemblies:

One bracket

One Phillips flathead screw

Four M2.5 socket head cap screws

One thermal tape

The following items are recommended, but not included in the bracket

or sensor kits:

Loctite 410 (blue)

Cleaning wipes

2 mm hex Allen wrench

Phillips screwdriver

Figure 1. BWA-BK-012 and -014 parts

Install the BWA-BK-012 or -014 Bracket Using Thermal Tape

This example uses a QM30VT2 with BWA-BK-014. The same steps can be applied for a QM30VT1 with BWA-BK-014 or a

QM30VT2-SS-9M with BWA-BK-012. The provided thermal tape or desired epoxy could be used by following these steps.

1. Clean the bracket and sensor.
2. Place the sensor on top of the bracket so the countersunk hole is covered by the sensor and the four corner holes align.

Figure 2. BWA-BK-014 and QM30VT2 sensor

Figure 3. QM30VT2 mounted on the BWA-BK-014 bracket

3. Screw the sensor to the bracket with the provided screws using a 2 mm Hex Allen wrench.

Figure 4. QM30VT2 screwed onto the BWA-BK-014 bracket

Bracket Assembly for the QM30VT Sensor

 

 

Original Document

213323 Rev. A

14 August 2019

213323