background image

2. If a bracket is needed, mount the device onto the bracket.
3. Select a reading distance.

The ABR 7000 manual adjustable focus models and Liquid Lens Autofocus models are both factory focused to a precise reading dis-
tance.

If this distance is compatible with your application, or if you have a Liquid Lens Autofocus model, you can use the Smart
Teach Interface to install the reader.

If this distance is not compatible with your application and you have a manual focus model, use the software setup procedure
described in the Instruction Manual.

The following table shows the Horizontal Field of View size for these factory focused reading distances:

Lens

Resolution

Factory Focused Reading Distance

Horizontal Field of View

6 mm

1.3 MP

85 mm (3.3 in)

121 mm (4.8 in)

9 mm

180 mm (7.1 in)

145 mm (5.7 in)

9 mm Liquid Lens Autofocus

135 mm (5.3 in) 3

109 mm (4.3 in)

12 mm

250 mm (9.8 in)

145 mm (5.7 in)

16 mm

320 mm (12.6 in)

132 mm (5.2 in)

9 mm Liquid Lens Autofocus

2 MP

100 mm (3.9 in) 3

95 mm (3.7 in)

16 mm Liquid Lens Autofocus

240 mm (9.4 in) 3

112 mm (4.4 in)

4. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten the mounting

screws at this time.

5. Check the device alignment.
6. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.

Connect the Cables

Table 2: Power and I/O Pinouts for MQDC2S-17xx

Pin

Wire Color

Description

1

Brown

Power Supply Input V (V dc)

2

Blue

Power Supply Input Voltage - (GND)

3

White

Input Signal 2 B (polarity insensitive)

4

4

Green

Transmit Data of Auxiliary RS232

5

Pink

External Trigger/Input 1 B (polarity insensitive)

6

Yellow

External Trigger/Input 1 A (polarity insensitive)

7

Black

ID-NET n

8

4

Gray

Output 2
NPN or PNP short circuit protected and software programmable

9

4

Red

Output 1
NPN or PNP short circuit protected and software programmable

13

White/Green

Input Signal 2 A (polarity insensitive)

14

4

Brown/Green

Receive Data of Auxiliary RS232

15

White/Yellow

ID-NET network -

16

4

Yellow/Brown

Output 3
NPN or PNP short circuit protected and software programmable

Connector Case

n/a

Cable shield connected to chassis and 17-pin connector shell
RS232 Main Serial Interface

RS422 FD Main Serial Interface

10

4

Violet

-

RX-

5

11

4

Gray/Pink

RX

RX+

5

 

12

4

Red/Blue

-

TX-

17

4

White/Gray

TX

TX+

If using a TCNM-ACBB1 connection box, connect the reader using cable MQDEC-1703SS-DB25 and refer to the Instruction Manual for writing

details.
Use Cat 5e or superior M12 D-code cables, such as STP-M12D-4xx.
To meet EMC requirements:

Connect the reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm

Connect pin "Earth" of the TCNM-ACBB1 connection box to a good earth ground

For direct connections, connect the cable shield to the locking ring nut of the connector

3 See 

Simple Configuration

 on p. 4 to perform the autofocus to optimize the reader for other distances.

4 Referenced to GND; any connected serial or I/O device must share a connection to GND. Outputs 1 and 2 become opto-isolated and polarity sensitive when connected

through the TCNM-ACBB1 connection box. See the Instruction Manual for connection details.

5 If using RS422, do not leave floating. See the Instruction Manual for connection details.

ABR 7000

 

 

P/N 207633 Rev. C

3

Summary of Contents for ABR7109-RSE2

Page 1: ...Ethernet 1D and 2D ABR7109 MSE2 9 mm manual focus Multicolored DPM 2 ABR7112 RSE2 12 mm manual focus Red ABR7116 RSE2 16 mm manual focus Red ABR7106 RSE2 6 mm manual focus Red ABR7106 MSE2 6 mm manua...

Page 2: ...a person s eye Mount open laser beam paths either above or below eye level where practical Terminate the beam emitted by the laser product at the end of its useful path Reference IEC 60825 1 2007 Sect...

Page 3: ...Green Transmit Data of Auxiliary RS232 5 Pink External Trigger Input 1 B polarity insensitive 6 Yellow External Trigger Input 1 A polarity insensitive 7 Black ID NET network 8 4 Gray Output 2 NPN or...

Page 4: ...Aim The Aim function turns on the built in laser pointer aiming system to aid reader positioning Because the laser pointers are centered on the FOV use them to position the imager on the code The Aim...

Page 5: ...n used in industrial PCs and or PLCs 1 Download the latest version of Barcode Manager from www bannerengineering com 2 Navigate to and open the downloaded file 3 Run Barcode Manager_Setup exe to acces...

Page 6: ...reader at the correct application reading distance 4 If needed focus the reader on the code 5 After the code is positioned click Pause to stop image acquisition Note If the image display area is too...

Page 7: ...de MAXICODE Aztec Code Dotcode Australia Post Royal Mail 4 State Customer Kix Code Japan Post PLANET POSTNET POSTNET BB Intelligent Mail Swedish Post FCC Statement Modifications or changes to this equ...

Page 8: ...air or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF P...

Reviews: