24
P/N 43298 rev. E
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
MINI-ARRAY
®
Instruction Manual
After a PSF is configured, it may be sent to the controller. The PSF may also be saved
for call-up at a later time. Many PSFs may be saved within PC files for quick controller
configuration whenever a setup change is required.
Parameter Setup Files Available for Each Controller Model
Analysis Mode
Selection
(See Section
5.5.3 for
descriptions of
these Analysis
Modes.)
MAC-1
MACP-1
MACN-1
MACV-1
MACI-1
MAC16N-1
MAC16P-1
ALL:
All data passed to host
x
x
x
FBB
: First Beam Blocked
x
x
x
LBB:
Last Beam Blocked
x
x
x
TBB:
Total Beams Blocked
x
x
x
CBB:
Contiguous Beams Blocked
x
x
x
FBM:
First Beam Made
x
x
x
LBM:
Last Beam Made
x
x
x
TBM:
Total Beams Made
x
x
x
CBM:
Contiguous Beams Made
x
x
x
SEG:
Segments
x
TRN:
Transitions
x
VHS:
Vehicle Separation
x
Blanking
Options
One or two fields may be
blanked
x
x
Blanking conditions are
unlimited
x
Output
Assignments
2 to 16 outputs, depending on model
Scanning
Methods
Straight Scan
Interlaced Scan
Edge Scan
Skip Scan
Control Mode
Selection
Continuous
scanning
Gate Mode:
scanning controlled by applying 10-30V dc to GATE input
Host Mode
: scanning controlled by host computer or PLC
Serial
Communication
Defines baud rate and controller I.D.
Serial
Transmission
Activates serial data transmission and specifies data format.
Controller Configuration
Summary of Contents for A-GAGE MINI-ARRAY MAC Series