Configuration • Service pages
66
Power Panel T30 User's manual V1.42 - Translation of the original documentation
5.1.6 Service page
Audio
On this service page, an audio signal can be configured for a touch gesture or controlled by an application.
Startup
Network
Time
Screen
Audio
Hand button
Buzzer
Buzzer
Default setting: Disabled
If this option is disabled, an audio signal is not output for a touch gesture on the Power Panel.
The following settings can be made when
Buzzer
is enabled:
Startup
Network
Time
Screen
Audio
Hand button
VNC
Web
Storage
Update
Buzzer
✓
Buzzer source
Touch
Buzzer frequency
40 to 15000 Hz
4000
Buzzer duration
10 to 500ms
10
Test buzzer
Press to test
Buzzer source
Default setting: Touch screen
The following options are available for triggering a buzzer:
Touch
, an audio signal is output for each touch gesture. This takes place independent
of the application controlled by the Power Panel operating system.
App
The RFB extension and corresponding library can be used to allow the application to trigger the audio
signal.
"Audio signal output" on page 92
Buzzer frequency
Default setting: 4000
Entry range: 10 to 15000
Unit: Hz
This setting is used to configure the frequency of the generated audio signal.
Buzzer duration
Default setting: 10
Entry range: 10 to 500
Unit: ms (milliseconds)
This setting is used to configure the duration of the generated audio signal.
Test buzzer
(Button)
Function: Testing the buzzer (sound is produced).