Software
138
Automation PC 3100 User's manual V 1.00
Translation of the original documentation
4.1.6.1.1 Create RAID volume
BIOS parameter
Setting options
Description
Name:
String
Default:
Volume1
Name for the RAID volume
No special characters are permitted.
Range: Max. 16 characters
RAID0 (stripe)
RAID1 (mirror)
RAID level:
Recovery
Selects the RAID level
Select disks:
(Blank)
X
M
Disk n:
R
Selects the storage medium for the RAID volume. Either X (RAID0 and RAID1) or M
(master) /R (recovery) can be defined (recovery mode).
4 KB
8 KB
16 KB
32 kB
64 KB
Stripe size:
128 KB
Selects the data block size [kB]
Capacity:
INT
Defines the RAID memory size [MB]
Range: Hardware-dependent
If storage media of different sizes are used, this is limited to the smaller medium.
Continuous
Synchronization:
On request
Selects the synchronization mode
Table 151: Device manager - Create RAID volume
4.1.6.1.2 Disk
n
BIOS parameter
Setting options
Description
Volume actions
1)
Reset to non-RAID
1)
Enter
Resets the disk to non-RAID
Port:
-
Displays the port number of device
n
Model number:
-
Displays the product ID of device
n
Serial number:
-
Displays the serial number of device
n
Size:
-
Displays the memory size of device
n
Status:
-
Displays the RAID status of device
n
Controller type:
-
Displays the controller of device
n
Controller interface:
-
Displays the controller interface of device
n
Table 152: Device manager - Intel® Rapid Storage Technology
1)
Available only if the storage medium is part of a RAID volume.
4.1.6.1.3 RAID volume info
BIOS parameter
Setting options
Description
Volume actions
Delete
Enter
Deletes the RAID volume
Enable master disk only
Enter
Enables only the master disk
Enable recovery disk only
Enter
Enables only the recovery disk
Name:
-
Displays the name of the RAID volume
RAID level:
-
Displays the RAID level of the volume
Strip size:
-
Displays the data block size [kB] of the volume
Size:
-
Displays the memory size [GB or TB] of the volume
Status:
-
Displays the status of the volume
Bootable:
-
Displays the bootability of the volume
Disk
n
1)
Enter
Table 153: Device manager - Intel® Rapid Storage Technology - RAID volume info
1)
"Disk n" is a placeholder. This BIOS parameter displays a subset of the values that are listed in more detail in the corresponding submenu.
StockCheck.com