1. Installation
Panel PC 800 devices are best mounted in a housing cutout using the clamps found on the
housing (different designs possible).
The terminal blocks are designed for a maximum thickness of 10 mm for the material where the
device is being clamped.
In order to tighten or loosen the screws, a hex key (size 3) is required for the plastic clamps and
a Torx screwdriver (size 20) or a large flat-head screwdriver for the aluminum die casting.
The maximum torque when tightening the clamp is 0.5 Nm. A Panel PC 800 unit must be
mounted to a flat surface. Uneven areas can cause damage to the display when the screws are
tightened.
Figure 58: Terminal block
Plastic (PA6)
with clip
Aluminum dye cast
with clip
Aluminum dye cast
without clip
Close
Open
Close
Open
Close
Open
Clamping le
ve
r
Clamping le
ve
r
Clamping le
ve
r
Clips