5.8 Four Automation Panel 900 units via SDL AP Link
An Automation Panel 900 unit is connected to the optional SDL transmitter (AP Link) via an SDL cable. Three other
Automation Panels of the same type are connected to this Automation Panel and operated via SDL. All four panels
show the same content (Display Clone).
USB is supported up to a maximum distance (SDL segment 1 + SDL segment 2) of 30 m on the first two panels
(front and back side). From a distance of 30 m and longer, USB is only available for the first panel (front and back
side). USB devices can only be connected directly to the Automation Panel (without a hub).
Automation PC 810
With AP Link
5AC801.SDL0-00
SDL Segment 1
Max. 40 m
Link: 5DLSDL.1000-01
No USB
possible
Link: 5DLSDL.1000-01
Link: 5DLSDL.1000-00
SDL Segment 2
Max. 40 m
SD
L
Se
gm
en
t 3
M
ax
. 4
0
m
SDL Segment 4
Max. 40 m
No USB
possible
USB
possible
Link: 5DLSDL.1000-01
USB OK
SDVO-C
Internal device number on the APC
Independent of segment length
Depends on segment length
AP Link
Connection
Figure 90: Four Automation Panel 900 units via SDL AP Link (sample photo)
5.8.1 Basic system requirements
The following table shows the possible combinations of APC810 system unit and CPU board to implement the
configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this is
also indicated (e.g. when connecting a non-B&R Automation Panel 900 device).
with system unit
CPU board
5PC810.SX01-00
1)
5PC810.SX02-00
5PC810.SX03-00
5PC810.SX05-00
Limitation
Resolution
5PC800.BM45-00
-
✓
✓
✓
Max. UXGA
5PC800.BM45-01
-
✓
✓
✓
Max. UXGA
Table 154: Possible combinations of system unit and CPU board
1)
AP Link cannot be installed.
5.8.2 Link modules
Information:
A corresponding link module must be selected for every device used.
Model number
Description
Note
5DLSDL.1000-00
Automation Panel Link SDL receiver
Connection for SDL in, transfer of display data, touch screen, USB 1.1, matrix keys, and service data, 24
VDC (screw clamp 0TB103.9 or cage clamp 0TB103.91 sold separately).
For Automation Panel 900
5DLSDL.1000-01
Automation Panel Link SDL transceiver
Connections for SDL in, transfer of display data, touch screen, USB 1.1, matrix keys, and service data,
24 VDC (screw clamp 0TB103.9 or cage clamp 0TB103.91 sold separately).
For Automation Panel 900
5AC801.SDL0-00
APC810 AP Link SDL transmitter
Automation Panel SDL link transmitter
For Automation PC 810
Table 155: Link modules
5.8.3 Cables
Select an Automation Panel 900 cable from the following table.