Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
217
2.8.11.9 Save reference
Saving a frequency reference value using a logic input command lasting longer than 0.1 s.
•
This function is used to control the speed of several inverters alternately via a single analog reference and
one logic input for each inverter.
•
It is also used to confirm a line reference (communication bus or network) on several inverters via a logic
input. This allows movements to be synchronized by getting rid of variations when the reference is set.
•
The reference is acquired 100 ms after the rising edge of the request. A new reference is not then acquired
until a new request is made.
F: Motor frequency
Movement command
Llx (saved)
Setpoint
[SAVE REFERENCE] (SPM-)
Code
Name/Description
Factory settings
SPM-
[SAVE REFERENCE]
SPM
[Save reference]
[No]
(nO)
nO
[No]
(nO)
: Function not active
LI1
[LI1]
(LI1)
to
[LI6]
(LI6)
-
Assignment to a logic input
LI6
Function active if the assigned input is at 1.