background image

 8BVI0014HWD0.000-1

Data sheet V 1.4

1

8BVI0014HWD0.000-1

1 General information

Uncontrolled and safe stops integrated

Integrated connection for motor holding brake and temperature sensor

2 slots for ACOPOSmulti plug-in modules

2-axis modules contain two complete standalone inverters in one inverter module

2 Order data

Model number

Short description

Figure

Wall mounting

8BVI0014HWD0.000-1

ACOPOSmulti inverter module 1.9 A, HV, wall mounting, 2 axes

Required accessories

Terminal block sets

8BZVI0055D0.000-1A

Screw clamp set for ACOPOSmulti 8BVI00xxHxD0 modules: 1x

8TB2112.2010-00, 1x 8TB2108.2010-00, 1x 8TB2104.203L-00,

1x 

8TB2104.203F-00, 

1x 

8TB3104.204G-11, 

1x

8TB3104.204K-11

8BZVI0055D0.500-1A

50x  Screw  clamp  terminal  block  set  for  ACOPOS-

multi  modules  8BVI00xxHxD0:  1x  8TB2112.2010-00,  1x

8TB2108.2010-00, 1x 8TB2104.203L-00, 1x 8TB2104.203F-00,

1x 8TB3104.204G-11, 1x 8TB3104.204K-11

8BZVI0055D0.A00-1A

100x  Screw  clamp  terminal  block  set  for  ACOPOS-

multi  modules  8BVI00xxHxD0:  1x  8TB2112.2010-00,  1x

8TB2108.2010-00, 1x 8TB2104.203L-00, 1x 8TB2104.203F-00,

1x 8TB3104.204G-11, 1x 8TB3104.204K-11

Optional accessories

Accessory sets

8BXB000.0000-00

ACPmulti accessory set for encoder buffering consisting of: 1

lithium battery AA 3.6 V; 1 protective cap for battery holder

Fan modules

8BXF001.0000-00

ACOPOSmulti fan module, replacement fan for ACOPOSmulti

modules (8BxP / 8B0C / 8BVI / 8BVE / 8B0K)

Plug-in modules

8BAC0120.000-1

ACOPOSmulti plug-in module, EnDat 2.1 interface

8BAC0120.001-2

ACOPOSmulti plug-in module, EnDat 2.2 interface

8BAC0121.000-1

ACOPOSmulti plug-in module, HIPERFACE interface

8BAC0122.000-1

ACOPOSmulti plug-in module, resolver interface 10 kHz

8BAC0123.000-1

ACOPOSmulti plug-in module, incremental encoder and SSI ab-

solute encoder interface for RS422 signals

8BAC0123.001-1

ACOPOSmulti plug-in module, incremental encoder interface for

5 V single-ended and 5 V differential signals

8BAC0123.002-1

ACOPOSmulti plug-in module, incremental encoder interface for

24 V single-ended and 24 V differential signals

8BAC0124.000-1

ACOPOSmulti plug-in module, SinCos interface

8BAC0125.000-1

ACOPOSmulti plug-in module, SinCos EnDat 2.1/SSI interface

8BAC0130.000-1

ACOPOSmulti plug-in module, 2 digital outputs, 50 mA, max.

62.5 kHz, 2 digital outputs, 500 mA, max. 1.25 kHz, 2 digital

inputs 24 VDC

8BAC0130.001-1

ACOPOSmulti plug-in module, 2 digital outputs, 50 mA, max.

62.5 kHz, 4 digital outputs, 500 mA, max. 1.25 kHz

8BAC0132.000-1

ACOPOSmulti plug-in module, 4 analog inputs ±10 V

8BAC0133.000-1

ACOPOSmulti  plug-in  module,  3  RS422  outputs  for  ABR  en-

coder emulation, 1 Mhz

POWERLINK cable

X20CA0E61.00020

POWERLINK connection cable, RJ45 to RJ45, 0.2 m

X20CA0E61.00025

POWERLINK connection cable, RJ45 to RJ45, 025 m

X20CA0E61.00030

POWERLINK connection cable, RJ45 to RJ45, 03 m

X20CA0E61.00035

POWERLINK connection cable, RJ45 to RJ45, 035 m

X20CA0E61.00050

POWERLINK connection cable, RJ45 to RJ45, 0.5 m

X20CA0E61.00100

POWERLINK connection cable, RJ45 to RJ45, 1 m

Shield component sets

8SCS000.0000-00

ACOPOSmulti shield component set: 1 shield plate 1x type 0, 1

hose clamp, B 9 mm, D 12-22 mm

8SCS002.0000-00

ACOPOSmulti  shield  component  set:  1x  clamping  plate;  2x

clamps D 4-13.5 mm; 4x screws

Table 1: 8BVI0014HWD0.000-1 - Order data

Summary of Contents for 8BVI0014HWD0.000-1

Page 1: ...at 2 2 interface 8BAC0121 000 1 ACOPOSmulti plug in module HIPERFACE interface 8BAC0122 000 1 ACOPOSmulti plug in module resolver interface 10 kHz 8BAC0123 000 1 ACOPOSmulti plug in module incremental...

Page 2: ...0014HWD0 000 1 General information B R ID code 0x26DF Cooling and mounting method Wall mounting Slots for plug in modules 2 Certification CE Yes KC Yes UL cULus E225616 Power Conversion Equipment Func...

Page 3: ...Max extinction energy per switching operation 1 5 Ws Max switching frequency 0 5 Hz Protective measures Overload and short circuit protection Yes Open circuit monitoring Yes Undervoltage monitoring Y...

Page 4: ...reases the CPU load When using 2 axis modules the increased CPU load reduces the functionality of the drive if this is not taken into consideration the computing time can be exceeded in extreme cases...

Page 5: ...Green Ready RUN Orange Run Inverter axis 2 ERR Red Error See inverter axis 1 Status of backup battery BAT Green Red Ready Error see Backup battery LED status indicators on page 6 Power supply 24 V Gr...

Page 6: ...ing green 2x Cyclic operation on the network is taking place but the client itself is not yet a participant Blinking green 3x Cyclic operation of the client is in preparation Solid green The client is...

Page 7: ...ts after 3 000 ms Status LED Indicator RDY RUN 1 Boot procedure for base hardware active ERR RDY RUN 2 Network configuration active ERR RDY RUN 3 Waiting for network telegram ERR RDY RUN 4 Network com...

Page 8: ...ientations Figure 2 Dimension diagram and installation dimensions 1 n Number of slots on the mounting plate 2 For proper air circulation at least 60 mm clearance must be available above the mounting p...

Page 9: ...B S2 B S2 T T T T X5B X5A U U V V W W PE PE X1 X2 S2 B S1 B Enable 1 COM 8 S2 B COM 5 S1 B Trigger2 Enable 2 COM 4 COM 1 COM 1 Enable 1 Trigger1 COM 7 24V Out 2 COM 3 24V Out 1 COM 9 Enable 2 ACOPOSmu...

Page 10: ...e g via the S1 S2 connections instead of via the internal transistor then the internal quenching circuit has no effect In this case the customer must make sure that neither the relay contact nor the b...

Page 11: ...that neither the relay contact nor the braking coil are damaged when switching off the brake This can be done by interconnecting the coil or better still interconnecting the contact with a quenching...

Page 12: ...e safely isolated circuits These connections are therefore only permitted to be connected to devices or components that have sufficient isolation in accordance with IEC 60364 4 41 or EN 61800 5 1 Caut...

Page 13: ...X5B connector Pinout X5B Name Function Axis 2 Protective ground conductor W Axis 2 Motor connection W V Axis 2 Motor connection V U Axis 2 Motor connection U W V U Table 14 X5B connector Pinout 6 1 8...

Page 14: ...lding brake Plug in module 8BAC0120 000 1 8BAC0121 000 1 8BAC0122 000 1 8BAC0123 00x 1 8BAC0124 000 1 Plug in module 8BAC0120 000 1 8BAC0121 000 1 8BAC0122 000 1 8BAC0123 00x 1 8BAC0124 000 1 8BAC0125...

Page 15: ...8BVI0014HWD0 000 1 Data sheet V 1 4 15 Figure 7 Motor...