B&R 5COSD4.1002-00 User Manual Download Page 1

SDL4/DVI Converter

User's manual

Version:

1.12 (April 2020)

Order no.:

MASDL4DVI-ENG

Translation of the original documentation

All values in this manual are current as of its creation. We reserve the right to change the contents of this manual

without notice. B&R Industrial Automation GmbH is not liable for technical or editorial errors and defects in this

manual. In addition, B&R Industrial Automation GmbH assumes no liability for damages that are directly or indirectly

attributable to the delivery, performance or use of this material. We point out that the software and hardware

designations and brand names of the respective companies used in this document are subject to general trademark,

brand or patent protection.

Summary of Contents for 5COSD4.1002-00

Page 1: ...Industrial Automation GmbH is not liable for technical or editorial errors and defects in this manual In addition B R Industrial Automation GmbH assumes no liability for damages that are directly or i...

Page 2: ...2 SDL4 DVI Converter for Automation PCs 8 3 3 Connection options 9 3 3 1 SDL4 DVI connection option 9 3 3 2 General limitations characteristics 10 3 3 2 1 USB endpoint analysis 10 3 4 Design Configura...

Page 3: ...larations 33 9 1 1 CE marking 33 9 1 2 EMC Directive 33 9 2 Certifications 34 9 2 1 UL certification 34 9 2 2 EAC 34 10 Accessories 35 10 1 General accessories 35 10 1 1 Accessories Order data 35 10 2...

Page 4: ...mation that warns of dangerous functions or situations Signal word Description Danger Failure to observe these safety guidelines and notices will result in death severe injury or substantial damage to...

Page 5: ...ical assemblies with housing Do not touch the connector contacts of connected cables Do not touch the contact tips on circuit boards Electrical assemblies without housing The following applies in addi...

Page 6: ...e g wire cross sec tion fuse protection protective ground connection 2 6 Operation 2 6 1 Protection against contact with electrical parts In order to operate programmable logic controllers operating...

Page 7: ...subsidiaries are not liable for damages and or losses in connection with security breaches unauthorized access malfunctions digital intrusion data leakage and or theft of data or information The afor...

Page 8: ...industrial PCs see the respective user s manuals Information All specifications in dimension diagrams and associated tables are in millimeters mm 3 2 SDL4 DVI Converter for Automation PCs The SDL4 DVI...

Page 9: ...or Panel B R industrial PC USB devices DVI D cable SDL3 SDL4 cables SDL4 DVI Converter Power supply SELV PELV Power supply Maximum cable length for SDL4 100 m Maximum cable length for DVI and USB 5 m...

Page 10: ...There is no direct relation between the number of endpoints and the number of devices supported by a USB port Devices SDL4 technology currently supports up to seven USB devices Hubs are not counted s...

Page 11: ...DVI SDL3 SDL4 PoE cables Select 1 5CASD3 0030 00 5CASD3 0050 00 5CASD3 0100 00 5CASD3 0150 00 5CASD3 0200 00 5CASD3 0300 00 5CASD3 0500 00 5CASD3 1000 00 DVI cables Select 1 5CADVI 0018 00 5CADVI 0050...

Page 12: ...SDL3 SDL4 PoE cables 5CASD3 0030 00 SDL3 SDL4 FT50 cable 3 m FT50 including Power over Eth ernet 5CASD3 0050 00 SDL3 SDL4 FT50 cable 5 m FT50 including Power over Eth ernet 5CASD3 0100 00 SDL3 SDL4 FT...

Page 13: ...Temperature Operation 0 to 55 C 2 3 Storage 20 to 60 C Transport 20 to 60 C Relative humidity Operation 5 to 90 non condensing Storage 5 to 95 non condensing Transport 5 to 95 non condensing Vibratio...

Page 14: ...r s manual V1 12 3 5 1 4 Dimensions Information All specifications in dimension diagrams and associated tables are in millimeters mm 2D and 3D diagrams DXF and STEP formats can be downloaded from the...

Page 15: ...device is only permitted to be supplied with a SELV PELV power supply or with safety extra low voltage SELV per EN 60950 The necessary 3 pin connector is not included in delivery for suitable accessor...

Page 16: ...unctionality For example a copper strip must be attached to the ground connection at a central grounding point of the control cabinet or system in which the device is installed The wire cross section...

Page 17: ...ontrol signal data 22 TMDS clock shield Shield of clock pair 8 Not connected Not connected 23 TMDS clock DVI clock positive 9 TMDS data 1 DVI lane 1 negative 24 TMDS clock DVI clock negative 10 TMDS d...

Page 18: ...Due to the variety of USB devices available on the market B R cannot guarantee their functionality The functionality of USB devices available from B R is guaranteed USB1 3 Standard USB 2 0 Variant Ty...

Page 19: ...5 m 40 SDL3 SDL4 PoE cables 5CASD3 0030 00 SDL3 SDL4 FT50 cable 3 m FT50 including Power over Ethernet 37 5CASD3 0050 00 SDL3 SDL4 FT50 cable 5 m FT50 including Power over Ethernet 37 5CASD3 0100 00...

Page 20: ...and table exclusively show the thermal view of the complete system If additional space is required for operating or servicing the device or using accessories e g cable strain relief clips this must be...

Page 21: ...upply All covers and components accessories hardware and cables must be installed or secured before the device is connected to the power supply and switched on Installation Information Optional sets a...

Page 22: ...rting at low temperatures or in the event of large temperature fluctuations the collection of moisture in or on the device is not permitted Moisture can cause short circuits in electrical circuits and...

Page 23: ...on the back of the device allows the system to be installed on a top hat rail TS35 that corresponds to the EN 50022 standard 35 1 7 5 Figure 1 Top hat rail 5 2 1 Procedure 1 Attach the SDL4 DVI Conver...

Page 24: ...to the following figure and secured with the supplied locating screws M3 max tightening torque 0 5 Nm The length overhang is not permitted to be removed and the cable strain relief clip is not permit...

Page 25: ...1 1 Wiring Install the DC power cable on the terminal block power supply connector as shown in the figure below Conductors with a cross section of 0 75 mm2 to 1 5 mm2 and wire end sleeve must be used...

Page 26: ...4 DVI Converter User s manual V1 12 1 Carry out electrostatic discharge on the housing or at the ground connection 2 Connect the power supply connector to the B R device and tighten the mounting screw...

Page 27: ...iverted Connect the device to the central grounding point e g the control cabinet or the system using the shortest possible low resistance path Cable design with at least 2 5 mm per connection If a ca...

Page 28: ...onnecting cables When connecting or installing cables the bend radius specification must be observed For this specification see the technical data of the respective cable The maximum tightening torque...

Page 29: ...manual V1 12 29 5 6 Removing the SDL4 DVI Converter 5 6 1 Procedure 1 Pull the SDL4 DVI Converter downwards 1 and slightly in the opposite direction away from the top hat rail 2 This releases the loc...

Page 30: ...efore installing additional hardware the device must have been started up Caution Before the device is started up it must be gradually adapted to room temperature Exposure to direct heat radiation is...

Page 31: ...Software SDL4 DVI Converter User s manual V1 12 31 7 Software 7 1 Updates No updates are required for the SDL4 DVI Converter...

Page 32: ...for maintenance work 8 1 Repairs Complaints and replacement parts Danger Unauthorized opening or repair of a device may result in personal injury and or serious damage to property Repairs are therefor...

Page 33: ...Electromagnetic compatibility 2014 30 EU and are designed for industrial applications EN 61131 2 2007 Programmable controllers Part 2 Equipment requirements and tests EN 61000 6 2 2005 Electromagnetic...

Page 34: ...ical data in section Certifications or in the associated certificates 9 2 1 UL certification Ind Cont Eq E115267 Products with this mark are tested by Underwriters Laboratories and listed as indus tri...

Page 35: ...when operating the complete system All components listed in this manual have undergone intensive system and compatibility testing and been approved accordingly B R cannot assume any functional warrant...

Page 36: ...7 g EMC B bridge and open deck 2 Terminal block Note Protected against vibration by the screw flange Nominal data per UL Number of pins 3 female Type of terminal block Screw clamp terminal block vari...

Page 37: ...cable 100 m FT50 including Power over Ethernet Table 5 5CASD3 0030 00 5CASD3 0050 00 5CASD3 0100 00 5CASD3 0150 00 5CASD3 0200 00 5CASD3 0300 00 5CASD3 0500 00 5CASD3 1000 00 Order data 10 3 1 1 3 Te...

Page 38: ...Pollution degree per EN 61131 2 Pollution degree 2 Flame retardant IEC 60332 1 2 Oil and hydrolysis resistance EN 60811 2 1 90 C 7x24 h Degree of protection per EN 60529 Cables IP20 RJ45 connector IP2...

Page 39: ...n gn wh or bl wh bl or wh br br Shield 10 3 1 1 7 Wiring The following information and figure apply if a field assembled cable is used and connected to an RJ45 network connector e g patch panel instea...

Page 40: ...us E115267 Industrial control equipment DNV GL Temperature B 0 55 C Humidity B up to 100 Vibration A 0 7 g EMC B bridge and open deck 1 GOST R Yes Cable construction Wire cross section 28 AWG Shield I...

Page 41: ...ser s manual V1 12 41 10 3 2 1 4 Bend radius specification Connector Ferrite bead Ferrite bead Ferrite bead Bend radius Connector Ferrite bead Bend radius Ferrite bead Ferrite bead 10 3 2 1 5 Dimensio...

Page 42: ...3 2 1 6 Cable pinout If you wish to assemble a suitable cable yourself the cable must be wired according to this pinout Information Functionality is only guaranteed for the cables available from B R D...

Page 43: ...on see Installing the cable strain relief clip on page 24 10 4 1 2 Order data Model number Short description Figure Accessories 5ACCRHMI 0012 000 REP strain relief USB For SDL4 DVI Converter Table 9 5...

Page 44: ...tion of materials To ensure that devices can be recycled in an environmentally friendly manner it is necessary to separate out the different materials Component Disposal Programmable logic controllers...

Page 45: ...Publishing information SDL4 DVI Converter User s manual V1 12 45...

Page 46: ...formation 46 SDL4 DVI Converter User s manual V1 12 Publishing information B R Industrial Automation GmbH B R Strasse 1 5142 Eggelsberg Austria Telephone 43 7748 6586 0 Fax 43 7748 6586 26 office br a...

Reviews: