Technical data
4.1.4 Environmental properties
4.1.4.1 Temperature specifications
Because it is possible to combine different panels and link modules, the following table provides a component-de-
pendent overview of the maximum ambient temperatures resulting from these combinations.
Information:
The maximum specified ambient temperatures for operation were determined under worst-case con-
ditions. Experience has shown that higher ambient temperatures can be achieved with typical appli-
cations in Microsoft Windows, for example. The relevant test and assessment must be carried out in-
dividually by the user on site (reading out the temperatures in BIOS or using the ADI Control Center,
for example).
Information about worst-case conditions
•
BurnInTest V4.0 Pro from PassMark Software for simulating 100% interface utilization using loopback
adapters (serial interface, USB interfaces)
•
Maximum expansion and power consumption of the system
4.1.4.1.1 Maximum ambient temperature during operation
All temperature specifications in degrees Celsius
[°C] at 500 m above sea level,
non-condensing
.
Maximum ambient temperature with link module
The respective ambient temperature is typically derated
1°C per 1000 meters starting at 500 m above sea level.
5DLSDL.1001-00
SDL/DVI
5DLSD3.1001-00
SDL3
1)
5DLSD4.1001-00
SDL4
Maximum ambient temperature
60
60
60
5AP923.1215-00
✓
✓
✓
5AP923.1505-00
✓
✓
✓
5AP923.1906-00 up to Rev. D0
50
50
50
Single-touch
5AP923.1906-00, Rev. E0 or later
✓
✓
✓
5AP933.156B-00 up to Rev. C0
50
50
50
5AP933.156B-00, Rev. D0 or later
✓
55
55
5AP933.185B-00
50
50
50
5AP933.215C-00 up to Rev. C0
45
45
45
5AP933.215C-00, Rev. D0 or later
50
50
50
5AP933.240C-00 up to Rev. C0
45
45
45
Multi-touch
5AP933.240C-00, Rev. D0 or later
✓
✓
✓
1)
The max. ambient temperature for SDL3 link module 5DLSD3.1001-00 < Rev. A5 with corresponding panel is 5°C lower.
4.1.4.1.1.1 Determining the ambient temperature
1. Select the link module.
2. The rows specify the maximum ambient temperature of the complete system in conjunction with the respective
link module.
3. The panel determines if there are temperature limits.
°
If the installed component has a
"✓"
(check mark), it can be operated without any problems at the
maximum ambient temperature of the complete system.
°
If the installed component has a temperature specification (e.g. "45[°C]"), the ambient temperature
of the complete system is not permitted to exceed this value.
4.1.4.1.2 Maximum ambient temperature operation
The minimum ambient temperature for non-condensing operation is 0°C.
30
Automation Panel 9x3 User's manual 2.01