Software • BIOS options
Chapter 4
Software
Power Panel 500 User's Manual V 1.00
163
BIOS setting
Meaning
Setting options
Effect
Option for reporting fatal errors. All of the
functions in a multifunction device will
be monitored. The report for the Root
Port takes place internally inside the Root
Complex.
Disabled
Disables this function.
Enabled
Enables this function.
NFER
Non-Fatal Error Reporting
Option for reporting non-fatal errors. All
of the functions in a multifunction device
will be monitored. The report for the Root
Port takes place internally inside the Root
Complex.
Disabled
Disables this function.
Enabled
Enables this function.
CER
Correctable Error Reporting
Option for reporting non-fatal errors. All
of the functions in a multifunction device
will be monitored. The report for the Root
Port takes place internally inside the Root
Complex.
Disabled
Disables this function.
Enabled
Enables this function.
CT0
PCI Express Completion Timer T0
This option is used to enable/disable PCI
Express Completion Timer.
Info:
If the system detected an ROB
(Processor Reorder Buffer) Time-
out, then this setting should be set
to Enabled.
Disabled
Disables this function.
Enabled
Enables this function.
SEFE
System Error on Fatal Error
Option for generating a System Error, if a
fatal error is registered by a device on the
Root Port or on the Root Port itself.
Disabled
Disables this function.
Enabled
Enables this function.
SENFE
System Error on Non-Fatal Error
Option for generating a System Error, if
a non-fatal error is registered by a device
on the Root Port or on the Root Port it-
self.
Disabled
Disables this function.
Enabled
Enables this function.
SECE
System Error on Correctable Error
Option for generating a System Error, if
a correctable error is registered by a de-
vice on the Root Port or on the Root Port
itself.
Disabled
Disables this function.
Enabled
Enables this function.
A PME Interrupt is generated when a
PME message is received.
PME Interrupt
Power Management Event Interrupt
Option for generating a PME Interrupt.
An Interrupt is generated when a PME
Message is received from a PCIe device.
Disabled
Disables this function.
Enabled
Enables this function.
The Root Port is enabled to generate
SCI if Power Management is detected.
PME SCI
Option for generating an SCI if Power
Management is detected.
Disabled
Disables this function.
Enabled
Enables this function.
The Root Port is enabled to generate
SCI if a Hot-Plug is detected.
Hot Plug SCI
Option for generating an SCI if a Hot-
Plug is detected.
Disabled
Disables this function.
Table 88: US15W Advanced - PCI Express Root Port 1 setting options
1) These settings are only possible if
VC1 Enable
is set to
Auto
.
2) These settings are only possible if
ASPM
is set to
Enabled
.
3) These settings are only possible if
Automatic ASPM
is set to
Manual
.
Summary of Contents for 500 Series
Page 2: ...2 Power Panel 500 User s Manual V 1 00...
Page 4: ...4 Power Panel 500 User s Manual V 1 00...
Page 5: ...Power Panel 500 User s Manual V 1 00 5 Appendix A...
Page 40: ...Technical data Entire device 40 Power Panel 500 User s Manual V 1 00 2 4 11 Mode Node switches...
Page 210: ...Accessories CompactFlash cards 210 Power Panel 500 User s Manual V 1 00 3 3 6 Benchmark...