X20 system modules • Digital signal processing modules • X20DS1828
X20 system User's Manual 3.10
1337
4.16.4 X20DS1828
4.16.4.1 General information
The X20DS1828 module is equipped with a HIPERFACE encoder interface. This module can be used to evaluate
encoders installed in motors from other manufacturers as well as encoders for external axes (encoders that scan
any machine movement). The input signals are monitored, making it possible to detect open or shorted lines as
well as encoder supply failures.
•
HIPERFACE encoder interface
•
Encoder input monitoring
•
11 VDC and GND for encoder supply
•
NetTime function: Time stamp for position
HIPERFACE
HIPERFACE is a standard developed by Max Stegmann GmbH (
), which like EnDat incorporates
the advantages of absolute and incremental position measurement while also offering a read/write parameter
memory in the encoder. With absolute position measurement (the absolute position is sampled serially), a homing
procedure is usually not required. Where necessary, a multi-turn encoder should be installed. To save costs, a
single-turn encoder and a reference switch can also be used. In this case, a homing procedure must be carried out.
The incremental process allows the short delay times necessary for position measurement on drives with excep-
tional dynamic properties. With the sinusoidal incremental signal and the fine resolution in the HIPERFACE mod-
ule, a very high positioning resolution is achieved in spite of the moderate signal frequencies used.
NetTime position timestamp
Highly dynamic positioning tasks require not only the position value, but also the exact time at which the position
was determined. The module has a NetTime function for this, which adds a timestamp to the recorded position
with microsecond accuracy.
The module provides the PLC with the position value and timestamp as absolute time value. The NetTime mech-
anisms ensure that the PLC NetTime clock and the local NetTime clock on the module have exactly the same
absolute time at all times.
4.16.4.2 Order data
Model number
Short description
Figure
Digital signal processing and preparation
X20DS1828
X20 digital signal module, 1x HIPERFACE, NetTime module
Required accessories
Bus modules
X20BM11
Bus module, 24 VDC keyed, internal I/O supply continuous
Terminal blocks
X20TB12
X20 terminal block, 12-pin, 24 VDC keyed
Table 427: X20DS1828 - Order data
4.16.4.3 Technical data
Product ID
X20DS1828
Short description
I/O module
1x HIPERFACE interface
General information
B&R ID code
0xAEC7
Status indicators
Counting direction, operating status, module status
Diagnostics
Module run/error
Yes, using status LED and software status
Counting direction
Yes, using status LED
Table 428: X20DS1828 - Technical data