3.4.1 5ACCIF01.FPLS-000
3.4.1.1 General information
The 5ACCIF01.FPLS-000 interface option is equipped with a POWERLINK and RS232 interface.
•
1x POWERLINK interface managing or controlled node
•
1x RS232 interface
•
32 kB FRAM
•
Compatible with the APC2100 and PPC2100
3.4.1.2 Order data
Model number
Short description
Figure
Interface options
5ACCIF01.FPLS-000
Interface card - POWERLINK - RS232 - 32 kB FRAM
Optional accessories
Terminal blocks
0TB1210.3100
Connector - Female 10-pin - Cage clamp - Protected against
vibration by the screw flange
Table 58: 5ACCIF01.FPLS-000 - Order data
3.4.1.3 Technical data
Information:
The following characteristics, features and limit values only apply to this accessory and can deviate
from those specified for the complete system. The data specifications for the complete system take
precedence over those of individual components.
Product ID
5ACCIF01.FPLS-000
General information
LEDs
L2, L3
B&R ID code
0xE540
Certification
cULus
Yes
cULus HazLoc Class 1 Division 2
LISTED 2P61 ABCD BR T4
Controller
FRAM
32 kB
Interfaces
COM
Quantity
1
Type
RS232, modem-capable, not electrically isolated
Execution
10-pin, male
UART
16550-compatible, 16-byte FIFO
Max. baud rate
115 kbit/s
POWERLINK
Quantity
1
Transmission
100BASE-TX
Type
Type 4
1)
Execution
Shielded RJ45
Transfer rate
100 Mbit/s
Cable length
Max. 100 m between two stations (segment length)
Terminating resistors
No
Electrical characteristics
Power consumption
1.75 W
Table 59: 5ACCIF01.FPLS-000 - Technical data