Remote System
User's Guide

(Former NIHON BALLUFF co., Ltd.)

Mail :[email protected]     Web:http://www.b-plus-kk.com

Wireless Power Supply by

Surrounding metal

Mutual interference

Type code

C(mm)

RCS240AH

300

RCS240PH

Type code

A(mm) B(mm) C(mm)

RCS240AH

100

40

45

RCS240PH

If  you  are  installing  in  parallel  head,  to  avoid  the  effects  of 
mutual  interference,  please  attach  the  head  with  an  interval 
greater  than  or  equal  to  the  value  shown  in  the  table  below 
always.

To avoid influence of surrounding metal, keep minimum spacing.
Remove  metal  chips  or  metallic  debris  on  the  active  surface.
Metal chips or metallic debris generate may damage to device 
or cause unexpected trouble.

◆ Please note that the signal may become unstable (false signal or chattering) when the transmission distance and the center offset 
 are outside the specification range.
◆ The inzone signal is a preliminary signal for confirming that the output signal is established within the specification range. 
 Please note that it does not guarantee signals output outside the specification range. 

#

Attachment

᳧᳝

௨ୖ

᳧᳝

௨ୖ

᳧᳝

௨ୖ

᳧᳝

௨ୖ

Please make the following is greater than or equal to 
the number of R(mm) bending of the cable line.

・Active Cable and 

 Passive Cable :  R ≧ 50

・Signal Cable line : R ≧ 30

Power  supply  unit  and  Charging  unit,  in  order  to  obtain  a 
good  cooling  effect,  please  keep  as  shown  below  the  sepa-
ration  distance  between  the  surrounding  body  so  as  not  to 
block the airflow.

R

Center off-set and transmitting distance

The  permissible  center  off-set  of  the  feed  head  and  charging 
head, please be installed so that the total (X + Y) axis deviation 
of the width of the X-axis · Y-axis is the following table.

Direction Distance
G

≦ 10mm

X+Y

・As a display function, I can be found in the LED displays the status of the equipment.
・As a protective function, it has the ability to detect abnormalities such as overheating during charging.In that case, you can operate 

the protection circuitry to protect the equipment.

・It is equipped with a communication function, it performs radio communication with charging side between the power supply side, we 

are state control and charging.

The following shows the contents of the <display function>・<protection>.

※ If an abnormality is detected, the unit will stop the charging operation.

State of equipment

Display content

LED

P

L

M

H

F

C

I

N

Intermittent oscillation state

This  is  a  state  in  which  power  have  been  turned  on  to  the  power 
unit, passive head is not in the operating area of the active head.

State of charge (L)

Is charging. (Charging aim:less than about 50%)

State of charge (M)

Is charging. (Charging aim:about 70%)

State of charge (H)

Is charging. (Charging aim:about 90%)

Float charging state

If  the  charge  current  value  becomes  below  a  specified  value,  I  will 
move to this mode.

Charging voltage error

Battery  voltage  outside  of  adaptation  have  been  connected,  the 
voltage of the battery is down to abnormal. Please connect the cor-
rect battery.

Battery reverse connection or 
non-connection error

Battery terminal is turned in reverse, cable is disconnected. Please 
check terminal, the cable.

Over current error

Charging  current  was  increased  abnormally.  (8A  or  more)  Since 
there is a possibility of equipment failure, you must have inspection 
and repair.

Over voltage error

Charging voltage was increased abnormally. (About 33.5V or more) 
Since  there  is  a  possibility  of  equipment  failure,  you  must  have  in-
spection and repair.

Battery overheating

The battery becomes the specification temperature outside.
(Specification temperature is 0 °

 to 40 °

 degrees.)

 Please review the ambient temperature environment of the battery.
Or, thermistor is disconnected.

Input voltage error

Input voltage from the passive head is abnormal. Please check dis-
tance  and  center  off-set  between  the  heads  is  entering  specifica-
tions within. If you are still unable to resolve the problem, there is a 
possibility of equipment failure.

Head overheating

Head  temperature  has  become  used  to  the  maximum  temperature 
(80 ℃ ) or more. Please on the power again after cooling the heat. 
If you are still unable to resolve the problem, there is a possibility of 
equipment failure.

                                             

2017.07.

26

  

  

  T313402He

● Power supply unit side (RCS240-AC1)

P LMHFCIN

Each output signal is open-collector. The maximum current value and the maximum output voltage, please connect 

so as not to exceed the maximum value by referring to the following values  .  

Connect the load before doing so, please do not short-circuit the output signal.

PS 

PS 

ࢩ࣮ࣙࢺ࡟࡚ືస

P

P

L

+

L

-

M

+

M

-

H

+

H

-

F

+

F

-

C

+

C

-

I

+

I

-

N

+

N

-

1

2

3

4

5

6

7

8

9

10 11 12 13 14

① Connector for the active head

② Connector for the active head

③ Start-up signal

※ This is the ON / OFF signal of the power supply of the Active head.
    Either the ON / OFF switch operated by a separate, please use 
    always ON.  (With jumper. Factory) 

 ● Maximum load current : 50mA

 ● Maximum load voltage:  30V

<Input signal pin assignment>

Internal circuit

Vcc

Power Supply  unit

Load

To fit each condition, 
please select the load

④ Various output signal

Signal type

LED Contents

Input Start-up signal

P

Shorting this signal, performs the power supply to the power head, power head starts os-
cillating, and then start the communication signal and power supply to the powered head. I 
want intermittent oscillation if there is no reception head.

O u t -
put

Voltage monitor signal L

L

It needs charging for charging amount is reduced. (Charging aim:less than about 50%)

Voltage monitor signal M

M

If the charge has been reduced somewhat. (Charging aim:about 70%)

Voltage monitor signal H

H

It is almost fully charged. (Charging aim:about 90%)

Float charging signal

F

It turns on, when a charging current value turns into a rated value.

charging signal

C

I will turn OFF during charging ON, in charge cut-off and float charging start.

Inzone signal

I

I will if ON is in the transmission area within the Active head / Passive head.

Error signal

N

It turns on, if a battery error occurs.  

⑤ LED

Function

Internal circuit

Power supply unit

P

P

〇 +

〇−

C

More than 5cm

More than 5cm

More than 10cm

More than 5cm

G

X 軸方向

Y 軸方向

X-axis direction

Y-axis 

direction

A

B

C

Metal

Metal

Mounting og the ferrite clamp

フェライトクランプ

フェライトクランプ

フェライト
クランプ

電源ユニット

充電ユニット

給電ヘッド

受電ヘッド

Charging 
unit

Power 
Supply  
unit

Passive Head

Active Head

ferrite clamp

ferrite clamp

ferrite 
clamp

The  installation  of  the  bundled  ferrite  clamp  is  necessary  to  meet  a 
standard of the EMC(IEC61000-4-3).
Please attach a ferrite clamp to a power cable by 2 turns with the following 
points each.

・It is one within 20cm from a power supply unit
・It is one within 20cm from a power supply unit to the power cable of the 

 active head.

・It is one within 20cm from a passive head to the power cable of the 

 passive head.