Remote System
User's Guide
(Former NIHON BALLUFF co., Ltd.)
Mail :[email protected] Web:http://www.b-plus-kk.com
Wireless Power Supply by
Surrounding metal
Mutual interference
Type code
C(mm)
RCS240AH
300
RCS240PH
Type code
A(mm) B(mm) C(mm)
RCS240AH
100
40
45
RCS240PH
If you are installing in parallel head, to avoid the effects of
mutual interference, please attach the head with an interval
greater than or equal to the value shown in the table below
always.
To avoid influence of surrounding metal, keep minimum spacing.
Remove metal chips or metallic debris on the active surface.
Metal chips or metallic debris generate may damage to device
or cause unexpected trouble.
◆ Please note that the signal may become unstable (false signal or chattering) when the transmission distance and the center offset
are outside the specification range.
◆ The inzone signal is a preliminary signal for confirming that the output signal is established within the specification range.
Please note that it does not guarantee signals output outside the specification range.
#
Attachment
᳧᳝
௨ୖ
᳧᳝
௨ୖ
᳧᳝
௨ୖ
᳧᳝
௨ୖ
Please make the following is greater than or equal to
the number of R(mm) bending of the cable line.
・Active Cable and
Passive Cable : R ≧ 50
・Signal Cable line : R ≧ 30
Power supply unit and Charging unit, in order to obtain a
good cooling effect, please keep as shown below the sepa-
ration distance between the surrounding body so as not to
block the airflow.
R
Center off-set and transmitting distance
The permissible center off-set of the feed head and charging
head, please be installed so that the total (X + Y) axis deviation
of the width of the X-axis · Y-axis is the following table.
Direction Distance
G
≦ 10mm
X+Y
・As a display function, I can be found in the LED displays the status of the equipment.
・As a protective function, it has the ability to detect abnormalities such as overheating during charging.In that case, you can operate
the protection circuitry to protect the equipment.
・It is equipped with a communication function, it performs radio communication with charging side between the power supply side, we
are state control and charging.
The following shows the contents of the <display function>・<protection>.
※ If an abnormality is detected, the unit will stop the charging operation.
State of equipment
Display content
LED
P
L
M
H
F
C
I
N
Intermittent oscillation state
This is a state in which power have been turned on to the power
unit, passive head is not in the operating area of the active head.
●
State of charge (L)
Is charging. (Charging aim:less than about 50%)
●
●
●
●
State of charge (M)
Is charging. (Charging aim:about 70%)
●
●
●
●
State of charge (H)
Is charging. (Charging aim:about 90%)
●
●
●
●
Float charging state
If the charge current value becomes below a specified value, I will
move to this mode.
●
●
●
●
Charging voltage error
Battery voltage outside of adaptation have been connected, the
voltage of the battery is down to abnormal. Please connect the cor-
rect battery.
●
●
●
●
Battery reverse connection or
non-connection error
Battery terminal is turned in reverse, cable is disconnected. Please
check terminal, the cable.
●
●
●
●
Over current error
Charging current was increased abnormally. (8A or more) Since
there is a possibility of equipment failure, you must have inspection
and repair.
●
●
●
●
Over voltage error
Charging voltage was increased abnormally. (About 33.5V or more)
Since there is a possibility of equipment failure, you must have in-
spection and repair.
●
●
●
●
●
Battery overheating
The battery becomes the specification temperature outside.
(Specification temperature is 0 °
to 40 °
degrees.)
Please review the ambient temperature environment of the battery.
Or, thermistor is disconnected.
●
●
●
●
●
Input voltage error
Input voltage from the passive head is abnormal. Please check dis-
tance and center off-set between the heads is entering specifica-
tions within. If you are still unable to resolve the problem, there is a
possibility of equipment failure.
●
●
●
●
●
●
Head overheating
Head temperature has become used to the maximum temperature
(80 ℃ ) or more. Please on the power again after cooling the heat.
If you are still unable to resolve the problem, there is a possibility of
equipment failure.
●
2017.07.
26
T313402He
● Power supply unit side (RCS240-AC1)
P LMHFCIN
①
②
③
⑤
④
Each output signal is open-collector. The maximum current value and the maximum output voltage, please connect
so as not to exceed the maximum value by referring to the following values .
Connect the load before doing so, please do not short-circuit the output signal.
PS
PS
ࢩ࣮ࣙࢺ࡚ືస
P
P
L
+
L
-
M
+
M
-
H
+
H
-
F
+
F
-
C
+
C
-
I
+
I
-
N
+
N
-
1
2
3
4
5
6
7
8
9
10 11 12 13 14
① Connector for the active head
② Connector for the active head
③ Start-up signal
※ This is the ON / OFF signal of the power supply of the Active head.
Either the ON / OFF switch operated by a separate, please use
always ON. (With jumper. Factory)
● Maximum load current : 50mA
● Maximum load voltage: 30V
<Input signal pin assignment>
Internal circuit
Vcc
Power Supply unit
I
Load
To fit each condition,
please select the load
④ Various output signal
Signal type
LED Contents
Input Start-up signal
P
Shorting this signal, performs the power supply to the power head, power head starts os-
cillating, and then start the communication signal and power supply to the powered head. I
want intermittent oscillation if there is no reception head.
O u t -
put
Voltage monitor signal L
L
It needs charging for charging amount is reduced. (Charging aim:less than about 50%)
Voltage monitor signal M
M
If the charge has been reduced somewhat. (Charging aim:about 70%)
Voltage monitor signal H
H
It is almost fully charged. (Charging aim:about 90%)
Float charging signal
F
It turns on, when a charging current value turns into a rated value.
charging signal
C
I will turn OFF during charging ON, in charge cut-off and float charging start.
Inzone signal
I
I will if ON is in the transmission area within the Active head / Passive head.
Error signal
N
It turns on, if a battery error occurs.
⑤ LED
Function
Internal circuit
Power supply unit
P
P
〇 +
〇−
C
More than 5cm
More than 5cm
More than 10cm
More than 5cm
G
X 軸方向
Y 軸方向
X-axis direction
Y-axis
direction
A
B
C
Metal
Metal
Mounting og the ferrite clamp
フェライトクランプ
フェライトクランプ
フェライト
クランプ
電源ユニット
充電ユニット
給電ヘッド
受電ヘッド
Charging
unit
Power
Supply
unit
Passive Head
Active Head
ferrite clamp
ferrite clamp
ferrite
clamp
The installation of the bundled ferrite clamp is necessary to meet a
standard of the EMC(IEC61000-4-3).
Please attach a ferrite clamp to a power cable by 2 turns with the following
points each.
・It is one within 20cm from a power supply unit
・It is one within 20cm from a power supply unit to the power cable of the
active head.
・It is one within 20cm from a passive head to the power cable of the
passive head.