background image

Appendix 1.

Water-proof RJ-45 cable jack assembly

Strip Cable Sheath
Recommended Wire
Gauge: 24AWG

2

Insert The Lock Nut
Into The Housing.

3

Insert The Seal At 
The Back End Of  The 
Housing.

4

Insert The Cable All 
The Through.

Crimp The RJ45 Plug

1 Insert The Plug Into

The Hohsing And 

Keep The Plug Close 

To Housing.

1. First Tighten Lock  Nut

2. Then Screw Sealing

     Nut Torque Value

     Is 6~8Kgf/cm

10

Sealing Nut

Lock Nut

Seal

Housing

Gasket

RJ45 Plug

40.0(REF)

3.5(REF)

7.7

Crimp The RJ45 Plug

Plug

Lock Nut

Seal

Cable

1

5

6

7

 

 

 

 

Summary of Contents for E580 Series

Page 1: ...E580 Series Embedded SIM Installation Guide ...

Page 2: ...however is user settable in the web GUI Mount base Attach the mounting bracket Earth ground terminal It is necessary to connect a grounding wire to protect the CPE from ESD electrostatic discharges and lightning Ethernet port Connect to a computer using an Ethernet cable Reset button Short press to restart the device Long press for for 10 seconds to reset the settings to the factory default settin...

Page 3: ... 2 8mm x 1 and 19mm x 1 1 3 Be sure that one of the cables used is an outdoor grade CAT 5e or above Ethernet cable type and the length of the cables are adequate to reach the location of the CPE and indoor PPoE Warning 1 Do NOT start any traffic test ex throughput test and internet browsing before the installer returns to the ground 2 Do ground the CPE to provide protection from ESD electrostatic ...

Page 4: ...63 Quantity 1 M13 Washer Quantity 2 M13 Spring Washer Quantity 2 Q 1 2 Hexagon Nuts Quantity 2 E F Washer M8x22 OD mm Quantity 2 M8 Hexagon Nuts Quantity 2 G H Hex Head Bolt M5x35mm Quantity 2 Spring Washer M5 Quantity 6 I J K L Kit 3 Quantity 1 Washer M8 Quantity 1 Hex Head Bolt M5x20mm Quantity 4 Washer M5 Quantity 4 27 21 6 18 72 12 7 7 9 7 9 16 22 13 13 13 5 8 9 ...

Page 5: ...gn the mounting bracket on the wall Using the bracket as mounting template mark the positions to drill the holes Step 2 Assemble the bracket as shown in the illustration Step 3 Attach the bracket to the back of the CPE Step 4 Hang the CPE to the wall and secure the bracket using the designated screws and washers ...

Page 6: ...C D E F G H D E F G H I D C J Step 2 Step 1 Align the mounting bracket on the wall Using the bracket as mounting template mark the positions to drill the holes Step 2 Assemble the bracket as shown in the illustration Step 3 Attach the bracket to the back of the CPE ...

Page 7: ...the CPE port Note For best protection against dust and water ethernet cable MUST be fitted with a water proof RJ 45 jack Please see Appendix 1 for water proof RJ 45 cable jack assembly Step 4 Align a pole on the bracket and assemble the pole bracket as shown Step 5 Adjust the CPE position to an appropriate direction and secure the pole bracket using the designated screws and washers ...

Page 8: ...ia PoE adapter Data IN port Step 3 Plug the PoE adapter to an electrical outlet Using Passive PoE adapter E580A series Using Passive PoE adapter E580P series LTE Outdoor CPE PoE PC Laptop Network Hub Router Data IN P D OUT Step 2 Step 1 DATA IN P DATA OUT PO W ER IN Electrical outlet Step 3 LTE Outdoor CPE Adapter PC Laptop Network Hub Router Data IN P D OUT Step 2 Step 3 Step 1 DATA IN P DATA OUT...

Page 9: ...justment Step 1 Loose the top knob using the wrench as shown Step 2 Swivel the device to the left or right to face the direction of the base station Step 3 Secure the knob using the wrench after the position is fixed Vertical angle adjustment Step 1 Loose the side knob using the wrench as shown Step 2 Adjust the device position up or down to face the direction of the base station Step 3 Secure the...

Page 10: ...d properly For more detail information please go to http www bandrich com UM E580_Embedded_Series pdf to download User Manual Using web management Step 1 Enter the IP address http 192 168 1 1 of the CPE in your browser s address bar then press Enter Step 2 On the opening screen enter the username admin and password admin Step 3 Click OK to login to the main screen Step 4 Click one of the header ta...

Page 11: ... The Back End Of The Housing 4 Insert The Cable All The Through Crimp The RJ45 Plug 1 Insert The Plug Into The Hohsing And Keep The Plug Close To Housing 1 First Tighten Lock Nut 2 Then Screw Sealing Nut Torque Value Is 6 8Kgf cm 10 Sealing Nut Lock Nut Seal Housing Gasket RJ45 Plug 40 0 REF 3 5 REF 7 7 Crimp The RJ45 Plug Plug Lock Nut Seal Cable 1 5 6 7 ...

Page 12: ...receive Keep the best distance as possible from other devices that may cause interference Check if you can route the cable through the available ventilation holes to avoid unnecessary drilling and waterproofing the wall Disconnect the power cord first before mounting the CPE Otherwise this may result in personal injury due to electric shock Mounting Choose a solid wall ground to mount the CPE Moun...

Page 13: ...se station By pointing the CPE in the proper direction ensures that you receive the strongest signal Fine tune the signal by adjusting the orientation horizontally or vertically to increase the CPE signal strength To verify the signal strength level Check the LEDs on the front panel increasing lighted LEDs indicates stronger signal Access the web management and go to Status Mobile Network Informat...

Page 14: ...P N 68060211021 Rev A 68060211021 ...

Reviews: