![Bandit 2290 Operating & Parts Manual Download Page 78](http://html1.mh-extra.com/html/bandit/2290/2290_operating-and-parts-manual_3675053078.webp)
Bandit
74
Copyright 8/19
MODEL 2290
The female splines in the bearing block need to be packed with an EP-2 Lithium type grease every six
months or every 1000 hours. To do this, unbolt the hydraulic pump from the bearing block and slide the
hydraulic pump out of the bearing block. There is no need to loosen or remove the hydraulic lines. Once the
hydraulic pump is removed from the bearing block, inspect the internal splines of the bearing block and the
external splines of the hydraulic pump. The tops of the splines should be fl at. If the splines are pointed, they
are wore and need to be replaced. If the splines are good, pack the internal splines of the bearing block with
an EP-2 Lithium type grease, reinstall the hydraulic pump, and bolt the hydraulic pump to the bearing block.
The fl uid in the bearing block needs to be checked weekly and kept full with an 80W/90 type gear lube.
See the Weekly Maintenance for the capacity, if needed.
Parts may not be exactly as shown.
NOTICE
SERVICING BEARING BLOCK
INTERNAL SPLINES OF
THE BEARING BLOCK
EXTERNAL SPLINES OF
THE HYDRAULIC PUMP
BEARING BLOCK
HYDRAULIC PUMP
MAINTENANCE