![B&G Network DATA Manual Download Page 12](http://html1.mh-extra.com/html/bandg/network-data/network-data_manual_460176012.webp)
12
If the log or boat speed is in error by a known percentage
then this method allows the calibration figure or
LOG CAL
to
be adjusted by that amount. The calibration figure is
measured in Hertz per knot (Hz/kt), the factory set value is
6.25.
NOTE
: The accuracy of this method is dependant upon the
accuracy of the calculated percentage error.
Using the factory set
LOG CAL
of 6.25 Hz/kt:
If the display is under reading by 10% subtract 0.62,
If the display is over reading by 10% add 0.62.
Press
SPEED
key to display
current boat
speed.
Press
SETUP
key
four times to
display
LOG
CAL
.
Press
ENTER
key to adjust the
displayed value.
Use
!
or
"
to
change the value.
Press
ENTER
to
store the new
value in memory.
Press
SPEED
key to complete
change.
METHOD 2. - MANUAL CALIBRATION - LOG CAL