H3000 Pilot Handbook
85
HB-3001-03
Clutch voltage Selection
The ACP computer unit can output different clutch/solenoid voltages depending
upon the size of the rudder drive unit fitted. The clutch/solenoid valve is only
required for rams or rotary drive units. This is achieved by setting dip switches on
the computer drive PCB in the lid of the computer unit.
Set the switches as per the table below. The default setting is 9V, (switch 4 ON)
suitable for size 1, 12V rams and size 2, 12V rams.
ACP DIP Switch Selection
DIP Switch
Clutch Voltage
Drive Size / Type
1
24V
24V Rotary
2
18V
Size 3, 24V Ram
3
12V
12V Rotary
4
9V
Size 1 & 2, 12V Rams
Note:
when using drives from another manufacturer, it is important to refer to the
documentation supplied with that drive to determine the correct clutch voltage
selection. Refer to the manufacturer of the drive for further information.