B&G FLEX-A-LITE 2600 User Manual Download Page 2

¼ Turn

½ Turn

¾ Turn

1 Turn

Setting

Fog - Tiny droplets, not visible

Fog - Tiny droplets, not visible

Mist - Larger droplets, visible

Mist - Larger droplets, visible

Description

40

44

52

56

Droplet Size

(VMD, in 

microns)

0.33/9.76

0.75/22.19

1.2/35.50

2.5/73.96

Flow Rate

(oz/ml per min)

PARTS AND PART LIST

Figure 4

CARE, MAINTENANCE, AND REPLACEMENT 

PARTS

Always empty and flush the tank and hose after each use; never leave 

chemicals in machine for extended periods of time.

Inspect spray hose and electric cord for wear or damage.

Protect nozzle when not in use.

Clean the filters on the bottom plate of the fogger regularly by 

removing and gently rinsing with clean warm water, then allowing to 

fully dry before reinserting. Replace when damaged as these protect 

the motor.

User Manual

FLEX-A-LITE 2600 FOGGER

1

29103230

1608003992
1608003993

1608004427
1208001339

29103240

95151362
29103225

Clip
Spring

Venturi
Knob assembly

2

3
4
5
6
7
8

Number Description

Order 

Number

(US)

Order

Number

(EU)

29103220

1608003991
1208001340
1608004029
1608004000

29103235
29108215
29103292

O-Ring
Sleeve
Screw
Screw

9

29103297

1608004003
1608004005
1608004001

29103299
29103293

Hex nut
Spacer
Nozzle

10
11

13
14

29103294

1608004002
1208001381

29108247

Screw
Hose assembly 

18” (46 cm)

1608003887

22071433

Spring clamp

12

OPERATION

Follow all “Before Use” instructions above.

Connect unit to the designated electrical 

supply:

  Do not connect 120V units to 230V 

 power,

  Do not connect 230V units to 120V  

 power.

  If using an extension cord, ensure it’s

 

3-prong and grounded.

Turn on fogger by moving switch to “on.”

1.

2.

3.

4.

5.

6.

Figure 3

Turn the adjustment knob from ¼ of a turn to fully open depending on 

what droplet size is appropriate for your application (Figure 3). Note 

that droplet size varies with temperature and viscosity of the material 

being dispensed.

Direct fog to treatment areas using the flexible hose.

IMPORTANT

 When application is finished, first close adjustment knob 

and second turn off power (Figure 4). Only then, open tank cap. Failure 

to follow this sequence can result in liquid dripping into the hose and 

destroying the motor. 

2