Airplane Manual FK 9
B&F Technik Vertriebs GmbH
Revision 20
Emergency Procedures
page 3-2
3.6.
Emergency Landing
Glide speed
100 km/h flaps pos. 1
Emergency field
select
Emergency call (121,5 MHz)
perform
Throttle
close
Electrical fuel pump
OFF (ROTAX only)
Fuel selector
OFF (ROTAX only)
Ignition / Battery switch
OFF
Safety belts
pull tight
Final, landing assured:
Flaps
full down
Approach speed
90 km/h
The glide can be controlled by changing airspeed, flap setting or slip. Use
caution, flaps in position 2 cause a lot of drag. Airspeed indication remains
valid during slip. Touchdown should be achieved at minimum speed.
3.7.
Strong Vibrations
Caused by engine or propeller:
Ignition
OFF
Airspeed
reduce
Emergency landing
perform respective Abnormal List
Caused by the fuselage / wings:
Airspeed
reduce
3.8.
Steering Problems
Aircraft uncontrollable with remaining flight controls:
Throttle
close
Ignition
OFF
Rescue system
activate
Electrical fuel pump
OFF (ROTAX only)
Fuel selector
OFF (ROTAX only)
Emergency call (121,5 MHz)
perform
Battery switch
OFF
Safety belts
pull tight
Doors
unlatch