10 / 22

23536 GB/2017-03

1

 electronic GmbH & Co. KG  •  Heinrichstraße 3-4  •  12207 Berlin  •  Deutschland  •  [email protected]

1.5  

Warnings and safety precautions  

General

•  Use the generator, the accessories and the cleaning agents in accordance with the 

operating instructions and the product information.

•  Keep the generator and cleaning agents out of the reach of children and also of 

persons who have not been instructed in their operation by reference to these 
instructions.

•  In the case of incorrect use, the manufacturer assumes no responsibility for 

the product's safety or functional ability. In the case of unauthorised alterations/
modi

fi

 cations, the 

!

 conformity will also become invalid.

•  The generator may only be operated by specialist personnel.
•  The generators must be protected so that no liquids seep in!
•  Do not expose the generator to corroding in

fl

 uences. 

•  Keep the generator's surface and controls clean and dry!
•  The generator may not be positioned in wet rooms. To protect it from moisture 

(splash water, steam, oil, oil mist, etc.), the generator must be set up a suitable 
distance away from the cleaning tank and other machines.

•  If the unit is passed on to others, the operating instructions with the safety 

instructions must also be handed over.

Operation and transport

•  Position the generator in a dust-free room (take the Environmental Conditions in 

chapter 1.4 into consideration).  

•  Place the generator on a dry, 

fi

 rm surface. 

•  In order to avoid overheating, do not install the generator in an enclosed housing. 

The air supply to the underside/sides of the generator must not be impeded.

•  On the mains side, the generators must only be connected to grounded mains 

operating voltages with protective systems. Here, the intended supply voltage for the 
generator must be observed.

•  Only turn on the HF generator if the ultrasonic oscillating tank is connected (HF 

cable) – never run the HF generator without a load.

•  Cavitation noises are emitted during ultrasonic cleaning. 

When working continuously within a radius of 5 m from the cleaning tanks or 
oscillating systems, wear ear protection for protection against injuries to health!

Summary of Contents for SONOREX TECHNIK TG 100

Page 1: ...valid for TG 50 Z to TG 500 Z Instructions for Use 23536 GB 2017 03 3 4 HF generators for operation of ultrasound transducers TG TG Z...

Page 2: ...d have no legal effect In case of any discrepancies between the translation and the original of this document the original version will take precedence BANDELIN accepts no responsibility or liability...

Page 3: ...or functional ability in the event of improper handling or usage contrary to the intended purpose In the event of unauthorised alterations modifications both the warranty claim and the conformity will...

Page 4: ...afety precautions 10 2 Preparation 12 2 1 Scope of delivery 12 2 2 Installation connection 12 2 2 1 HF connection for ultrasonic transducer 12 2 3 Start up 13 3 Operation 13 3 1 Mains plug TG 13 3 2 T...

Page 5: ...cable 17 6 3 Error analysis 17 6 4 Customer service 18 6 4 1 Repairs and service 18 6 4 2 Decontamination certificate 18 7 Accessories 19 7 1 Required accessories not applicable 19 7 2 Chemical prepar...

Page 6: ...ype specification and serial number are found on the type plate on the underside of the generator Product features HF generator in a low maintenance robust aluminium housing 1 Depending on the model w...

Page 7: ...nd and thus into mechanical energy 1 2 Purpose SONOREX TECHNIK HF generators produce low frequency ultrasound and are intended for the sonication of aqueous fluids through connected transducers e g fi...

Page 8: ...ight 1 2 kg 1 3 kg 3 0 kg 3 4 kg 3 7 kg HF generator with integrated time switch TG 50 Z TG 100 Z TG 200 Z TG 300 Z TG 500 Z Current consumption 0 3 A 0 5 A 0 9 A 1 4 A 2 2 A Ultrasonic peak power 200...

Page 9: ...contamination 2 Permitted ambient temperature 5 to 45 C Permissible relative humidity up to 31 C 80 Permissible relative humidity up to 40 C 50 Condensation not allowed Degree of protection IP 20 pur...

Page 10: ...ms To protect it from moisture splash water steam oil oil mist etc the generator must be set up a suitable distance away from the cleaning tank and other machines If the unit is passed on to others th...

Page 11: ...schland info bandelin com Damage and defects Use only the connection material supplied Defective parts must only be replaced with SONOREX original parts or parts of the same quality In the case of def...

Page 12: ...ng to order see delivery note 2 2 Installation connection Place the generator on a firm level and dry surface In doing so the maximum weight depending on the housing size and number of power modules m...

Page 13: ...knob to the right Time range 1 15 mins Once the time has elapsed the time switch automatically turns off By turning the knob back the operating time will be shortened or the generator will be turned o...

Page 14: ...embled units are completely covered filled with liquid During use in tanks or similar containers the specified filling level must be observed Tanks After refilling or longer idle periods the liquid sh...

Page 15: ...nnected Step 2 Prepare for sonication To do so see the corresponding Instructions for Use for assemblies ultrasonic transducer systems etc Prepare the sonicating medium and check that the fill level i...

Page 16: ...pply to damages caused by the use of unsuitable disinfecting agents or detergents 5 1 Cleaning and care Cooling of the generator The generator must be cleaned regularly Every 6 months dust should be r...

Page 17: ...sis SONOREX HF generators are robustly constructed and designed for a high level of reliability Nevertheless the possibility of a malfunction due to a defective component can never be fully discounted...

Page 18: ...tions for delivery and payment of BANDELIN electronic GmbH Co KG apply In addition the HF generator must be cleaned and decontaminated if necessary see the following chapter 6 4 2 Decontamination cert...

Page 19: ...DELIN recommends the TICKOPUR or STAMMOPUR concentrates by DR H STAMM GmbH which have been especially developed for ultrasound use and which utilise the ultrasound optimally Additional information may...

Page 20: ...ries must be cleaned pursuant to current laws and regulations and if necessary must also be disinfected with a surface disinfection agent listed by the VAH Device type Serial number Accessories Device...

Page 21: ...ories contained in this package have been cleaned and or disinfected pursuant to current laws and regulations and that the information provided in this declaration is correct and complete Company Inst...

Page 22: ...Note The user instructions in this and other languages as well as further information can be found on the enclosed CD...

Reviews: