background image

18

Power Drive & Roll-A-Pro

®

  installation instructions

19. Door Status Indicators 

Door Status Indicators

OPEN LED (green)

CLOSE LED (red)

Beeper

Open

On

Close

On

Opening

Flashing

Closing

Flashing

Door travel stopped

Flashing

Flashing

Door obstructed when opening

Flashing

Beeps while door is 

moving

Door obstructed when closing

Flashing

Beeps while door is 

moving

Opener overloaded

Alternating flashes

Alternating flashes

Mains power interrupted

Rapid flashes

Button

Function

1.  OPERATE

Opens/stops/closes the door.

2. CODE SET LED (Red)

Flashes when a code is being stored or when the transmitter button is pressed

3. CLOSE LIMIT LED (Red)

Illuminates and flashes as the door closes, and remains on when the close limit 

position has been reached.

4. OPEN  LIMIT LED (Green)

Illuminates and flashes as the door opens and remains on when the open limit 

position has been reached.

5. SERVICE LED (Yellow)

Indicates when the opener requires service or repairs.

6. CODE SET and MINUS (-)

Is used for storing or erasing transmitter buttons for door operation

18. User Operating Controls 

02

03

04

01

06

05

Summary of Contents for Controll-A-Door RDO-1V4

Page 1: ...Door Opener installation instructions Power Drive Roll A Pro These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161061...

Page 2: ...fications 19 21 Troubleshooting 20 22 After Installation Care 22 22 1 Service Checklist 22 22 2 Battery Replacement 23 22 3 Battery Disposal 23 22 4 Warranty 23 WARNING IMPORTANT SAFETY INSTRUCTIONS F...

Page 3: ...n instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact wh...

Page 4: ...or service BATTERY WARNING This product contains a lithium button coin cell battery in the transmitters If a new or used lithium button coin cell battery is swallowed or enters the body it can cause s...

Page 5: ...t Transmitter Roll A ProTM 3 x TB 7 Transmitters 1 x Wall Visor Clip 4 1 x Collar Kit 5 1 x Weight Bar Fastner Bag 6 2 x Nilock Nut 7 2 x 2 x 3 16 x 1 2 flat washers 8 2 x Pan Head Screw M4 x 50 9 2 x...

Page 6: ...s to be fitted at least 135mm to the bracket is required Therefore the recommended sideroom from the edge of the door curtain is 95mm to the inside of the door bracket and 135mm to the wall as per dia...

Page 7: ...then the door may require servicing 5 2 8 5 Door Preparation 5 1 Prepare the Door a Clean the guides if there is any oil or wax present using a suitable white spirit The only lubricant suitable for us...

Page 8: ...the end opposite to where the opener will be fitted check that the U bolt which holds the door axle to the bracket is tightened securely b Open the door completely and tie rope around the door roll D...

Page 9: ...string down to disengage opener Slide opener over door axle c Secure with two 2 Flat washers 12 and two 2 Hex serration head screws 13 d Check the drive gear rotates freely by pulling the string hand...

Page 10: ...S T E P T W O HOLD Press to close door S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as this can interfere with the eas...

Page 11: ...initiate a re profile LIMITS must already be set opener beeps once RELEASE S T E P T H R E E opener beeps once Then refit controls cover 10 3 Controller memory reset S T E P O N E S T E P T W O C O N...

Page 12: ...d not exceed 20 kg CAUTION Take care when completing a safety test Failure to follow this warning can result in serious personal injury and or property damage WARNING If the door is closing and is una...

Page 13: ...80 ma V EB1 0V EB2 0V OSC AUX External device Alarm Door or Gate opener V EB1 0V EB2 0V OSC AUX 12 3 Remote Aerial Some sites cause poor radio reception Particularly problematic areas are those where...

Page 14: ...from remote controllers that have been programmed into its memory Up to 64 remotes 8 for Roll A Pro can be programmed S T E P T H R E E Switch power on Press and release HOLD for 3 sec HOLD for 3 sec...

Page 15: ...imes S T E P F I V E Turn on HOLD for 4 sec RELEASE Turn off Press then try another remote LED will be lit and light flash LED will go out Refit controls cover 14 5 Coding for AUX Output A U X O U T P...

Page 16: ...er ALL stored codes deleted S T E P T W O HOLD for 6 sec RELEASE LED will flash rapidly 14 8 Installing the Wall Mounted Transmitter S T E P T H R E E I N S T A L L I N G W A L L R E M O T E C O N T R...

Page 17: ...e t h e o p e n e r a f t e r t h e d o o r i s c l o s e d T O E N G A G E T H E O P E N E R WA R N I N G P l e a s e t e s t t h e m a n u a l r e l e a s e m e c h a n i s m t o e n s u r e t h a...

Page 18: ...pted Rapid flashes Button Function 1 OPERATE Opens stops closes the door 2 CODE SET LED Red Flashes when a code is being stored or when the transmitter button is pressed 3 CLOSE LIMIT LED Red Illumina...

Page 19: ...350N Short Term Peak Force 600N 60kg 500N 50kg Nominal force 200N 20kg 200N 20kg Receiver type Multi frequency Multi frequency Receiver code storage capacity 64 x Tri Tran 4 button Transmitters 8 x Tr...

Page 20: ...r The transmitter range varies or is restricted Variations are normal depending on conditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the...

Page 21: ...ared Clear away any obstructions and test door closes correctly If door is damaged contact your door professional Remove all power sources including the battery backup Wait till all lights are out 10...

Page 22: ...ening of door mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure...

Page 23: ...Battery Disposal 22 2 Battery Replacement Some batteries are less toxic but hazardous for other reasons Lithium batteries can explode or catch fire in landfill while button cells are dangerous if swa...

Reviews: