background image

Wiring and Installation Instructions

Safety Beam Kits

 

EASYBEAM P.E. 3-V1 KIT 

ATA ORDER NO. 61904, B&D ORDER NO. 62626

ITEM DESCRIPTION

QTY

14

EASYBEAM RX-TX SET

1

4

MOUNTING KIT 

1

PE 2000TS KIT - 

ATA ORDER NO. 61903, B&D ORDER NO. 62852

ITEM DESCRIPTION

QTY

15

PE BEAM IR-2000TS

1

4

MOUNTING KIT

1

ACCESSORY KIT - 

16

RESISTOR 2K2 PACK

1

17

RESISTOR 5K6 PACK

1

INTERFACE KIT V2 (ACB / DCB BOARDS ONLY) - 

18

HARNESS P.E. RX 24AWG 10M

1

19

HARNESS P.E. RX-TX 17M

1

EasyBeam

TM

 PE-3v1

PE 2000TS

WPE-1V1 KIT -  

ATA ORDER NO. 61957,  B&D ORDER NO. 70300

ITEM DESCRIPTION

QTY

1

WPB-04.02 TX ASSEMBLY

1

2

WPB-04.02 RX ASSEMBLY

1

3

WPB-04.03 BASE STATION ASSEMBLY

1

4

MOUNTING KIT 

1

FLUSH MOUNTING KIT - 

5

PEB4-W1 BRACKET

2

6

TAPTITE SCREW “P” M3 X 8

8

7

SELF TAPPING SCREW M6 X 25

4

8

PLASTIC WALL PLUG 6.7 X 25

4

PEB4-W1 HARDWARE KIT 2 - 

9

PLASTIC WALL PLUG 6.9 X 25

2

10

SELF TAPPING SCREW M6 X 25

2

11

TAPTITE SCREW “P” BLACK ZNC M3 X 12

8

12

HEX SERRATION FLANGE NUT M6

1

13

HEX SERRATION HEAD SCREW M6 X 16

1

Wireless WPE-1v1

Important Safety Instructions

 

WARNING!

• 

When using Safety beams, the doorway / gateway must be clear of all obstructions and 
persons a all times. The location of the beams and manner in which they are installed 
might not give safety protection at all times. 

• 

The sensors need to be 100mm above the floor level, however, the exact position must 
be chosen in such a manner that it suits the application, the environmental conditions 
and provides maximum safety protection.

• 

When using auto close mode, a Safety beam must be fitted correctly and tested for 

operation at regular intervals. Extreme caution is recommended when using auto close 

mode. All safety rules must be followed.

 

ELECTROCUTION!

• 

Disconnect the power cord from mains power and battery backup (if installed) before 
making any repairs or removing covers on openers.

CAUTION:

Fall from ladder

• 

Ensure ladder is the correct type for job.

• 

Ensure ladder is on flat ground.

• 

Ensure user has 3 points of contact while on ladder.

Entrapment 

• 

Ensure the garage door / gate is in good working order by undertaking regular servicing.

• 

Safety beams must be installed if the closing force at the bottom edge of the door / gate 
exceeds 400N (40kg)

Doc # 160044_07
Part #  13409
Released 14/12/17

Summary of Contents for Automatic Technology Wireless WPE-1v1

Page 1: ...nt Safety Instructions WARNING When using Safety beams the doorway gateway must be clear of all obstructions and persons a all times The location of the beams and manner in which they are installed might not give safety protection at all times The sensors need to be 100mm above the floor level however the exact position must be chosen in such a manner that it suits the application the environmenta...

Page 2: ...verse or stop the door gate movement There are three 3 different types of Safety Beam Kits available and they are not compatible with all products Please refer to table below for product and Safety Beam compatibility Mounting Brackets All three 3 types of Safety Beam Kits use the same mounting brackets MOUNTING KIT ITEM DESCRIPTION QTY 1 PE 2000TS BRACKET 2 2 ADJUSTMENT BRACKET 2 3 MOUNTING BRACKE...

Page 3: ...th the safety beams connected The green LED on the transmitter should turn ON to indicate power is present b If the receiver is connected to power and the red LED is flashing while the green LED on the transmitter is on the transmitter and receiver are not aligned c Make horizontal and or vertical adjustment on the transmitter and or receiver until the red LED on the receiver turns on indicating a...

Page 4: ...o be attached directly to a sectional opener using the M6 x 16 Hex serration head screw 13 and M6 Hex serration flange nut 12 The wire can be fed through the top gromet of the opener NOTE The bracket may also be rotated so the base station hangs above the power head Inserting batteries into receiver and transmitter a Insert two 2 C Type batteries in the Receiver WPB 4 02 RX by removing the front c...

Page 5: ... by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as close as possible to the door gate opening In industrial applications it is recommended that multiple Safety Beams are fitted Assemble Flush Mounting Kit for minimum sideroom applications For applications which have limited space available or certain environmental factors a flush mount...

Page 6: ...ring diagram for two 2 sets of safety beams Aligning the Transmitter and Receiver a Power up the opener with the safety beams connected The green LED on the transmitter should turn ON to indicate power is present b If the receiver is connected to power and the red LED is flashing while the green LED on the transmitter is on the transmitter and receiver are not aligned c Make horizontal and or vert...

Page 7: ...e cause Remedy Base station and receiver LED s constantly on Receiver is not coded into base station Code the receiver into base station Receiver LED constantly on but cannot close the door Receiver not coded into base station Mains power is not switched on to the opener Code the receiver into base station Switch on mains power Receiver LED is blinking and can not close the door Receiver and trans...

Page 8: ...es or faulty or It is a condition of the below warranties that the manual operating opening and closing force of the door by hand does not exceed 20kg MODEL WARRANTY DOOR MAX SECTIONAL GDO 9V2 7 yrs 20 000 cycles 200kg GDO 9V3 7 yrs 20 000 cycles 175kg GDO 11V3 5 yrs 10 000 cycles 110kg ROLLING GDO 6V3 5 yrs 10 000 cycles 110kg GDO 6V4 7 yrs 20 000 cycles 110kg GDO 8V3 2 yrs 5 000 cycles 100kg GDO...

Reviews: