B&B EIRM-EXTEND Quick Start Manual Download Page 2

Hardened Managed Ethernet Extender                                   

EIRM-EXTEND-0411qsg

 

2                                                                            

International Headquarters: 

815-433-5100  

www.bb-elec.com

European Headquarters: +

353 91 792444  

www.bb-europe.com

  

 

 

Console Configuration

 

 

Connect to the console of Hardened Ethernet Extender: 

Connect the DB9 straight cable to the DCE female RS-232 serial port of the device and the DTE male 

RS-232 serial port of the terminal or computer running the terminal emulation application.  Direct 

access to the administration console is achieved by directly connecting a terminal or a PC equipped 

with a terminal-emulation program (such as HyperTerminal) to the console port of Hardened Ethernet 

Extender. 

 

Configuration settings of the terminal-emulation program: 

Baud rate 

Data bits 

Parity 

Stop bit 

Flow control 

115,200bps 

none 

none 

 

Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below: 

 

And the “#” prompt will show on the screen. 

 

<Note> 

The procedures to restore factory default password: 

Connect to console  of Hardened Ethernet Extender  through  Microsoft Windows HyperTerminal.  Please 

power on Hardened Ethernet Extender and press “Ctrl” and “D” while Hardened Ethernet Extender is   

 

 

booting up to enter Bootloader. Input “reset password” command at Bootloader prompt and press “Enter”.   

Power off and on Hardened Ethernet Extender then Hardened Ethernet Extender is restored with factory 

default password. 

 

Web Configuration 

 

Login the Hardened Ethernet Extender: 

Specify the default IP address (192.168.1.10) of the Hardened Ethernet Extender in the web browser. 

A login window will be shown as below: 

 

 

Enter the factory default password (no password). 

Then click on the “Submit” button to log on to the Hardened Ethernet Extender. 

 