BB-200 Weighing Indicator – Programming and User’s Manual
Copyright © 2023 – B and B Scales, Inc. All Rights Reserved.
Page 22
For example, when you first enter Calibration Mode, you will see [C01]. Press “Print” and you will see
[C01 1]. Press “Print” again to advance to the next menu, [C02], etc.
When you are in Calibration Mode, use the keypad keys to navigate, as follows:
Table 10:
Keypad Navigation
Key
Function
Increase the value or move the cursor up
Decrease the value or move the cursor down
Move Left
Move Right
Save and Exit. This key is important – it SAVES the values you have just entered.
Return / Enter
Calibration and Programming Menus
The table below describes the calibration functions. Put the indicator in Calibration Mode as above.
When you see C01 on the display, follow the instructions below to calibrate the scale:
Menu Name
Description
Possible Values
Example / Notes
C01
Units Menu
Sets the unit that the
indicator weighs in.
1 = kg
2=lbs
3=g
4=oz
This is the default value that the indicator
will use. You can still switch between
pounds and kilograms with the
key in normal weighing mode.
C02
Decimal Menu
Sets the number of
zeros after the decimal
point.
1,2,3,4
Use the arrow keys to set the number of
decimals. For example, two decimals
would read 0.00.
C03
Graduations
Sets the scale
graduations
1,2,5,10,20,50
For example: Set to “1” to read to the
nearest 1 pound.
C04
Scale
Capacity
Sets the maximum
capacity of the scale.
No
Theoretical
Maximum.
Default is 10,000. 5000 is suggested for
most agricultural or industrial scales.
C05
Zero
Calibrates the scale at
zero.
0 = No, do not
calibrate.
1 = Yes,
If you are calibrating the scale, you
MUST calibrate the ZERO value and the
SPAN value together.