Before you can install the Ulinx Extender, you need to prepare your site.  

1.  Determine where the host computer is to be located and set up the 

computer. 

2.  Determine where you want to locate the USB device(s). 

3.  Decide whether the power adapter is to be connected to the Local 

Unit or the Remote Unit (see the discussion of power handling on 
page 4). 

4.  If you are using surface cabling, ensure you have enough Category 

5 UTP cabling to connect the two locations. 

OR 
    

If you are using premise cabling, ensure Category 5 UTP cabling 
is installed between the two locations, with Category 5 
information outlets located near both the computer and the USB 
device. 

Installing the Local Unit  

1.  Place the Local Unit near the host computer. 

2.  If the power adapter is to be located with the Local Unit: 

a)  Plug the power adapter into a suitable AC outlet. 

b)  Connect the power adapter to the Local Unit. 

3.  Plug the Type B connector on the USB cable (included) into the 

Host port on the Local Unit. 

4.  Plug the Type A connector on the USB cable into the USB port on 

the computer. 

Installing the Remote Unit  

1.  Place the Remote Unit near the USB device(s). 

2.  If the power adapter is to be located with the Remote Unit: 

a)  Plug the power adapter into a suitable AC outlet. 

b)  Connect the power adapter to the Remote Unit. 

 

6

 

Manual Documentation Number: UEC100M/4-2305 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – 

www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – 

www.bb-europe.com

 

Connecting the Local Unit to the Remote Unit  

 NOTE

To ensure proper operation, we recommend that only Category 5 
or better, Unshielded Twisted Pair (UTP) cabling be used to 
connect the Local Unit to the Remote Unit. The UTP cabling must 
have a straight-through conductor configuration with no 
crossovers, and must be terminated with 8-conductor RJ45 
connectors at both ends.  

With Surface Cabling 

1.   Plug one end of the Category 5 UTP cabling (not included) into the 

Link port on the Local Unit. 

2.   Plug the other end of the Category 5 UTP cabling into the Link port 

on the Remote Unit. 

With Premise Cabling 

1.   Plug one end of a Category 5 patch cord (not included) into the Link 

port on the Local Unit. 

2.   Plug the other end of the patch cord into the Category 5 information 

outlet near the host computer. 

3.   Plug one end of the second Category 5 patch cord (not included) 

into the Link port on the Remote Unit. 

4.   Plug the other end of the second patch cord into the Category 5 

information outlet near the USB device. 

 NOTE

: The maximum length of the Category 5 UTP cable, including 

patch cords, must not exceed 100 meters. 

Checking the Installation 

1.  Check that the Power LEDs on the Local Unit and Remote Unit 

are both on. 

2.  Check that the Link LEDs on the Local Unit and Remote Unit are 

both on. 

3.  Check that the Host LED on the Local Unit is on. 
4.  On the host PC, open the Device Manager applet. Expand the 

entry for Universal Serial Bus controllers by clicking the + sign. If 
the Ulinx Extender has been installed correctly you should find it 
listed as a Generic USB Hub. 

Summary of Contents for ULinx UEC100M/4

Page 1: ... com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb europe com Sales e mail sales bb europe com Technical Support e mail support bb europe com B B Electronics Mfg Co Inc June 2005 Manual Docume...

Page 2: ...rmful interference when installed and operated in a commercial environment The Ulinx Extender generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user guide may cause harmful interference to radio communications Operation of the Ulinx Extender in a residential area is likely to cause harmful interference in which case the user will be require...

Page 3: ...OUT THE ULINX EXTENDER 2 BEFORE YOU BEGIN 5 INSTALLING THE LOCAL UNIT 5 INSTALLING THE REMOTE UNIT 5 CONNECTING THE LOCAL UNIT TO THE REMOTE UNIT 6 CHECKING THE INSTALLATION 6 CONNECTING A USB DEVICE 7 TROUBLESHOOTING 8 SPECIFICATIONS 11 CONTACTING TECHNICAL SUPPORT 12 ii Manual Documentation Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100...

Page 4: ...th of the Category 5 UTP cable including patch cords must not exceed 100m 2 Manual Documentation Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com About the Ulinx Extender The Ulinx Extender b...

Page 5: ... bb europe com USB Cables USB cables have two distinct connectors The Type A connector is used to connect the cable from a USB device to the Type A port on a computer or hub The Type B connector is used to attach the USB cable to a USB device USB Type A port USB Type A connector USB Type B port USB Type B connector Power Handling Some USB devices are powered directly from the USB and do not requir...

Page 6: ...Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Connecting the Local Unit to the Remote Unit NOTE To ensure proper operation we recommend that only Category 5 or better Unshielded Twisted Pa...

Page 7: ...r further assistance see page 12 Symptoms Cause Remedy All LEDs on Local Unit and Remote Unit are off Cause The Ulinx Extender is not receiving power from the adapter 1 Ensure that the power adapter is connected to the Local Unit or Remote Unit 2 Check that the adapter is connected to a live source of electrical power Power LED on one unit is on power LED on other unit is off Cause There is no con...

Page 8: ...when directly connected to the computer connect another device of a different type to the Ulinx Extender Connect the Ulinx Extender to the computer 5 If the second device does not operate the Ulinx Extender may be malfunctioning Contact technical support for assistance 6 If the second device does operate properly the first device may not be compatible with the Ulinx Extender Contact technical supp...

Page 9: ...A Local Unit dimensions 10 7 x 8 4 x 3 4 cm 4 3 x 3 4 x 1 4 in Local Unit weight 0 3 kg 0 6 lb Remote Unit dimensions 10 7 x 8 4 x 3 4 cm 4 3 x 3 4 x 1 4 in Remote Unit weight 0 3 kg 0 6 lb Total system shipping weight 1 1 kg 2 4 lb Temperature range 4 C to 40 C Regulatory testing FCC CE Class A 12 Manual Documentation Number UEC100M 4 2305 B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Otta...

Reviews: