4. Configuring the MAP450D
The MAP450D has many operating parameters that control how it communicates
to the host controller. These operating parameters can be changed in three ways:
from the MAP450D’s keyboard when it is in Configuration mode, when the host
controller sends a Configuration Control Command, or by downloading a
STEPware-100 project. This chapter explains how to connect the MAP450D to a
PC so you can download a project from the STEPware-100 configuration software.
4.1. Connecting the MAP450D to a PC
First, remove the operating cable from the terminal block pins. Next, connect an
RS-232 serial communications cable (Maple Systems P/N 7431-0048) to the
proper COM port on your computer and the terminal block pins on the MAP450D.
See Figure 13 below for pin assignments.
INSTALLATION MANUAL
17
1010-0046A, REV 00
9S
10
COM
RXD
TXD
+24V
3
9
2
1
TB1
OIT
PC
Shield
+24V
GND
Power
Supply
CTS
DSR
RTS
DCD
DTR
GND
TXD
RXD
8
7
6
4
1
3
2
5
Red
Black
Black
Red
Blk
Green
White
Printer
Com2
Back
of
OIT
7431-0048
Com1
- +
OIT
GND
PC
OIT Power Supply
Maple Systems
OIT to PC cable
(If mouse is using
Com 1, use Com2)
Figure 13 MAP450D to PC RS-232 Communication