background image

 

38 

Manual Documentation Number: EIR508-2xx-T 0708m 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 

 

 

7.  Select outgoing frames as VLAN tagged or untagged and then click 

Apply

   

 

 

„

 

Port VID:

 Configure port VID settings

 

 
1. 

Port VLAN ID: 

Enter the port VLAN ID 

2. Click 

Apply

 

3.  To reset back to default value, click 

Default

 button 

 

Summary of Contents for EIR508-2-T Series

Page 1: ...8m 707 Dayton Road P O Box 1040 Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical Support e mail support bb elec com Fax 815 433 5104 European Headquarters B B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 7924...

Page 2: ... Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Eight Port Managed Industrial Ethernet Switches User Manual ...

Page 3: ...nstructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures...

Page 4: ... Ph 353 91 792444 Fax 353 91 792445 www bb europe com Content Introduction 8 Features 8 Package Contents 9 Hardware Description 10 Physical Dimension W x H x D 10 Front Panel 10 Reset Button 10 Bottom View 11 DIP switch 12 LED Indicators 14 Ports 15 Cabling 17 Wiring the Power Inputs 17 Wiring the Fault Alarm Contact 18 Mounting Installation 19 DIN Rail Mounting 19 Panel Mounting 21 Hardware Insta...

Page 5: ...1 792445 www bb europe com Network Application 23 X Ring Application 23 Coupling Ring Application 24 Dual Homing Application 25 Web Based Management 26 About Web based Management 26 Preparing for Web Management 26 System Login 26 Port status 28 Single Port Information 28 Port Statistics 29 Port Control 30 Switch Setting 31 Port Mirroring 32 VLAN configuration 33 Port based VLAN 33 802 1Q VLAN 36 A...

Page 6: ...792445 www bb europe com Power Alarm Configuration 42 IP Configuration 43 SNTP Configuration 44 IP Security 47 RSTP Configuration 48 System Configuration 48 Per Port Configuration 49 X Ring 51 QoS Configuration 52 IGMP 55 Security Manager 56 SNMP Configuration 56 System Options 57 Community strings 57 Trap Manager 58 Configuration Backup 58 TFTP Restore Configuration 58 TFTP Backup Configuration 5...

Page 7: ...L 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Save Configuration 61 Rate Control 61 System Log 62 System Log 62 Event Configuration 63 Trouble shooting 65 Technical Specifications 66 ...

Page 8: ...00TX ports all copper model Auto MDI MDI X Store and Forward switching architecture Wide range redundant power inputs DIN rail and panel mount design 2K MAC address table Web management GUI 4 priority queues per port IEEE 802 3x flow control Flow control with full duplex Back pressure with half duplex Class of service IGMP with Query mode for multi media application Ingress packet filter and egres...

Page 9: ... com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Package Contents One Industrial Ethernet Switch One Quick Start Guide One CD ROM containing users manual One DIN Rail Clip attached to the switch One panel mount plate and six screws If any item is damaged or missing contact B B Electronics ...

Page 10: ...h 353 91 792444 Fax 353 91 792445 www bb europe com Hardware Description Physical Dimension W x H x D 2 3 x 5 7 x 4 3 in 5 8 x 14 5 x 10 9 cm Front Panel Front Panel of the industrial switch Reset Button The reset button is used to restart the reboot the switch or restore it to the factory default configuration Restart Press the button for 2 seconds and release Set to factory default value Press t...

Page 11: ...5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Bottom View The bottom panel of the industrial switch has one terminal block connector within two DC power inputs and fault relay contacts Bottom Panel of the industrial switch ...

Page 12: ...P switch is used to configure the relay alarm ring master mode The default value for each position is OFF Software configuration is also required for the alarm relay The alarm relay contacts are normally open DIP Switch No Status Description 1 OFF Disable port 1 Alarm ON Enable port 1 Alarm 2 OFF Disable port 2 Alarm ON Enable port 2 Alarm 3 OFF Disable port 3 Alarm ON Enable port 3 Alarm 4 OFF Di...

Page 13: ...d Ph 353 91 792444 Fax 353 91 792445 www bb europe com ON Enable port 6 Alarm 7 OFF Disable port 7 Alarm ON Enable port 7 Alarm 8 OFF Disable port 8 Alarm ON Enable port 8 Alarm 9 OFF Disable the ring master function ON Enable the switch as the ring master in the X Ring group NOTE Restart the switch after the X Ring DIP switch is set NOTE The Alarm Relay Output requires software configuration in a...

Page 14: ... power input is available Power 1 Green Power source 1 is available Off Power source 1 is not available Power 2 Green Power source 2 is available Off Power source 2 is not available Fault Yellow Power failure or port failure See Alarm setting for operational details Off Normal Operation R M Ring Master Green The switch is the master of an X Ring group Off The switch is not the master of an X Ring ...

Page 15: ... RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx All copper ports on this switch support automatic MDI MDI X operation Straight through cables can be used for all network connections In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and...

Page 16: ...eland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Straight Through Cable Schematic Cross Over Cable Schematic Fiber Port Fiber Models Only There are two 100Base FX ports Depending on the model the fiber ports have either SC or ST type connectors and use multi mode 2Km or single mode 30Km cable Connect the fiber ports as described below ATTENTION This is a Class 1 Laser LED product Do not ...

Page 17: ...europe com Cabling Use Category 5 cabling for RJ 45 port connections The cable must be less than 328 ft 100 meters long Use 9 125 um cable for single mode fiber Distances up to 30 Kilometers are supported Use 50 125 or 62 5 125 cable for multi mode fiber Distances up to 2Km are supported Wiring the Power Inputs NOTE Use 12 24 AWG wire V V V V 1 Insert the positive and negative wires into the V and...

Page 18: ...europe com Wiring the Fault Alarm Contact The fault alarm contact is located in the middle of terminal block connector as shown below Insert the wires and set the Dipswitch to ON When a power source fails or a link fault occurs the relay contacts will close NOTE Use12 24 AWG wire NOTE Relay contacts are normally open NOTE The Relay Alarm also requires software configuration Refer to the Web Based ...

Page 19: ...0 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mounting Installation DIN Rail Mounting 1 Use the screws to screw the DIN Rail to the industrial switch 2 To remove the DIN Rail reverse the step 1 Rear Panel of the switch DIN Rail ...

Page 20: ...www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 1 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Ensure the DIN Rail is tightly secured on the track 4 To remove the industrial switch from the track reverse steps above ...

Page 21: ...tlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Panel Mounting 1 Remove the DIN Rail 2 Place the panel mount plate on the rear panel of the industrial switch 3 Attach the plate with the screws provided 4 Use the hook holes at the corners of the plate to mount the switch to the panel 5 To remove the panel mount plate reverse steps above ...

Page 22: ...ounting section If panel mounting is desired refer to Panel Mounting Section 3 Mount the switch 4 Apply power to the switch The power LED will light up 5 Connect CAT 5 cables to the industrial switch s RJ 45 ports and the network devices NOTE If the network devices do not support MDI MDI X a crossover cable will be required 6 Fiber Models Only Connect the fiber optic cables to the industrial switc...

Page 23: ...53 91 792444 Fax 353 91 792445 www bb europe com Network Application X Ring Application The EIR508 series of Industrial Switches incorporate the X Ring Protocol to ensure network reliability and system restoration within 300 ms in the event of a connection failure The X Ring algorithm is similar to the spanning tree protocol STP algorithm but it has faster recovery time The following figure below ...

Page 24: ...s Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Coupling Ring Application If the network has more than one X Ring group the coupling ring function is used to connect them and add redundancy This ensures that transmissions between the two ring groups will not fail The figure below is an example of the coupling ring application ...

Page 25: ...92445 www bb europe com Dual Homing Application The Dual Homing function is used to prevent a connection loss between the X Ring group and the upper level core switch Assign a port in each X ring group to be the Dual Homing ports The Dual Homing function can only be used when the X Ring function is active Each X Ring group can have one Dual Homing port NOTE In the Dual Homing architecture the uppe...

Page 26: ...t features and allows the switch to be configured from anywhere on the network The web site is designed for Internet Explorer 6 0 and uses Java Applets to reduce bandwidth consumption enhance access speed and present an intuitive user interface Preparing for Web Management Before using web management install the industrial switch on the network and verify that a PC on the local network can connect...

Page 27: ...ial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 1 Launch Internet Explorer on the PC 2 Enter http the IP address of the switch in the address window and then Press Enter 3 The login screen will appear 4 Enter the user name and password Press Enter or OK the home screen will appear Home Interface Configuration Display Screen Panel Figure Display Function Menu B...

Page 28: ...d mode ex 100TX 100Mbps Link Displays the ports status up or down State Displays the ports status disabled or enabled Unlinked is displayed as off Negotiation Displays the auto negotiation mode auto or forced Speed Duplex Displays the port connection speed Config is the configured value Actual is the current value Flow Control Displays the flow control status as Symmetric or Asymmetric in full mod...

Page 29: ...ax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Click the desired port on the Panel figure The single port information window will display the current port information Port information interface Port Statistics Displays port statistics ...

Page 30: ...t the port by scrolling down the Port column The current port information will be displayed in the table below 2 State Enables or disables the port 3 Negotiation Sets the negotiation mode to Auto Nway specify the speed duplex of the port and enable auto negotiation or Forced 4 Speed Sets the transmit speed of the port 5 Duplex Sets the port to full duplex or half duplex Flow control Sets flow cont...

Page 31: ... location and to view system information System Name Assigns a name to the switch The maximum length is 64 bytes System Location Assigns a physical location for the switch The maximum length is 64 bytes System Description Displays the description of switch This is read only and cannot be modified Firmware Version Displays the firmware version Kernel Version Displays the kernel software version Har...

Page 32: ... ports to a specifically designated port the mirror port 1 Port Mirroring Mode Sets the mirror mode Select disable to disable port mirroring Select TX to monitor data being transmitted by a port Select both to monitor port data being transmitted and received by a port The default value is Disable 2 Analysis Port This is the port used to see all monitored port traffic This port can be connected to ...

Page 33: ...ical equivalent of reconnecting a group of devices to another Layer 2 switch However the network devices retain their same physical connection The EIR508 series switches support port based and 802 1Q tagged based VLAN In the default configuration the VLAN option is disabled VLAN Configuration interface Port based VLAN With port based VLAN the port is assigned to a VLAN Therefore all devices attach...

Page 34: ...100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN PortBase interface 1 Click Add to add a new VLAN group The EIR508 series supports up to 64 VLAN 2 Enter Group name VLAN ID and select the members of VLAN group 3 Click Apply ...

Page 35: ... Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN PortBase Add interface 4 The VLAN group will be displayed after it is clicked 5 Click Next Page to view the next VLAN Group 6 Use the Delete button to delete unwanted VLANs 7 Use Edit to modify existing VLANs NOTE If the configuration is not saved it will be lost when the switch is powered off ...

Page 36: ... to be created across devices from different venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frame The tag contains a VLAN Identifier VID When the 802 1Q VLAN is enabled all ports on the switch belong to a default VLAN VID 1 The default VLAN can t be deled The EIR508 series will support up to 64 VLAN groups 802 1q VLAN interface Basic 1 Click Add 2 Management VLAN ID Us...

Page 37: ...e If the management VLAN ID is 101 and the VLAN Group ID 101 includes ports 1 2 and 4 only ports 1 2 and 4 can perform remote management functions on the switch If a port is in multiple VLAN groups it can still perform management functions as long as one VLAN group ID is equal to the Management VLAN ID 3 Group Name Assign a name for the new VLAN 4 VLAN ID Enter a VLAN ID 2 4094 The default is 1 5 ...

Page 38: ...4 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 7 Select outgoing frames as VLAN tagged or untagged and then click Apply Port VID Configure port VID settings 1 Port VLAN ID Enter the port VLAN ID 2 Click Apply 3 To reset back to default value click Default button ...

Page 39: ...353 91 792445 www bb europe com 802 1q VLAN Port VLAN ID interface NOTE If the configuration is not saved it will be lost if the switch is powered off Alert Email Alert Configuration When a specified event occurs the switch will send an alert email Email Alert Enables or disable the function SMTP Server IP Address Enter the mail server IP address Authentication Mark the check box to enable and con...

Page 40: ...ark Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mail Account Enter the email address used to send the alert Ex Switch 123 com This account must exist on the mail server Password The email account password Confirm Password Confirm the password E mail Address of Recipient 1 4 Enter up to 4 e mail accounts to receive the alert Click Apply Email Alert Configuration int...

Page 41: ...vents occur the system will send out an email alert Device cold start Sends an alert when the device executes a cold start Power status Sends an alert when the power status changes i e power source 1 removed SMNP Authentication Failure Sends and alert when an SNMP authentication failure occurs X Ring topology change Sends an alert when X Ring topology has changes Port event selection An e mail ale...

Page 42: ...5 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Event Configuration interface Power Alarm Configuration The power alarm enables the relay alarm Mark the check box and click the Apply button Power Alarm interface ...

Page 43: ...ork DHCP server After the Apply button is clicked dialog box will indicate that the user that when the DHCP client is enabled the current IP will lost and the new IP must be looked up on the DHCP server The switch s MAC Address will be required to look up the new IP Address on the DHCP Server To cancel the DHCP client function click cancel IP Address Assign a static IP address This is not required...

Page 44: ...able SNTP Daylight Saving Time Enables or disables daylight saving time When enabled the daylight saving time period must be entered UTC Time zone Used to calculate local time Set the switch location time zone Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylig...

Page 45: ...Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European Russia Zone 1 2 hours 2 pm BT Baghdad Russia Zone 2 3 hours 3 pm ZP4 Russia Zone 3 4 hours 4 pm ZP5 Russia Zone 4 5 hours 5 pm ZP6 Russia Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CC...

Page 46: ... bb europe com Guam Standard Russia Zone 9 IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight SNTP Sever IP Enter the IP address of the SNTP server Switch Timer Displays the switch s current time Daylight Saving Period Enter the daylight savings period Daylight Saving Offset mins Configure the offset value in minutes Click Apply NOTE If the configuration is no...

Page 47: ...nd Ph 353 91 792444 Fax 353 91 792445 www bb europe com IP Security IP security function grants 10 specific IP addresses permission to access the switch through a web browser for the switch management 1 Enable the IP Security Mark the check box to enable 2 Security IP 1 10 Enter up to 10 specific IP Addresses 3 Click Apply NOTE If the configuration is not saved it will be lost when the switch is p...

Page 48: ...st priority and is selected as the root If the value changes the switch must be rebooted The priority value must be multiple of 4096 according to the protocol standard rule Max Age 6 40 the number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 and 40 Hello Time 1 10 The time that the control swit...

Page 49: ... and priority of every port Select the port in Port column Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 Priority Network priority Enter a number from 0 to 240 The value of priority must be a multiple of 16 Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon wheth...

Page 50: ... the P2P status of the link to be manipulated administratively True is P2P enabling False is P2P disabling Admin Edge The port directly connected to end stations cannot create a bridging loop To configure the port as an edge port set the port to True status Admin Non Stp The port includes the STP mathematic calculation True does not include the STP mathematic calculation False includes the STP mat...

Page 51: ... working ports If a network connection failure occurs the backup port will automatically become a working port to recover The switch has a Dipswitch to configure the switch as the ring master The ring master has the rights to negotiate and place a command to other switches in the X Ring group If more than one switch is in master mode the software will select the switch with lowest MAC address numb...

Page 52: ... Homing port In an X Ring group only one can be a Dual Homing port This function will only work when the X Ring function is enabled Click Apply X Ring Interface NOTE 1 When the X Ring function is enabled the RSTP function must be disabled 2 If the configuration is not saved it will be lost when the switch is powered off QoS Configuration Configure QoS setting of every port QoS Policy Select the Qo...

Page 53: ...ority will follow the default port priority assigned High middle low or lowest COS only The port will follow the COS priority assigned TOS only The port will follow the TOS priority assigned COS first The port will follow COS priority first and then another priority rule TOS first The port will follow TOS priority first and then another priority rule COS priority Set the COS priority level 0 7 TOS...

Page 54: ...ectronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com QoS configuration Interface ...

Page 55: ...s that support IGMP Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch IGMP has three fundamental types of messages Message Description Query A message sent from an IGMP router or switch requesting a response from each host belonging to the multicast group Report A message sent by a host indicating that the host wants to be o...

Page 56: ...ty Manager Use to change the web management login user name and password 1 User name Enter the new user name The default is root 2 Password Enter the new password The default is root 3 Confirm password Re type the new password 4 Click Apply Security Manager Interface NOTE If the configuration is not saved it will be lost when the switch is powered off SNMP Configuration The SNMP is a Protocol that...

Page 57: ...europe com SNMP Management interface System Options Name Enter a name for the switch Location Enter the switch physical location Contact Enter the name of contact person or organization Community strings Serve as a password Strings Enter the name of the string RO Read only Enables requests accompanied by this string to display MIB object information RW Read write Enables requests accompanied by th...

Page 58: ...he switch If there is no trap manager defined traps will not be issued Create a trap manager by entering the IP address of the station and a community string IP Address Enter the trap device IP Community Strings Enter The trap device community strings Click Add Configuration Backup Used to backup the configuration to a TFTP server and load the backup configuration from the TFTP server TFTP Restore...

Page 59: ...m TFTP Backup Configuration Save current flash ROM value to the TFTP server TFTP Server IP Address Enter the TFTP server IP Backup File Name Enter the file image name Click Apply TFTP Backup Configuration interface TFTP Update Firmware Use to update firmware Ensure the TFTP server is ready and the firmware image is stored on the TFTP server TFTP Server IP Address Enter the TFTP server IP Firmware ...

Page 60: ...cs Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Factory Default Reset the Switch to the default configuration NOTE The IP Address subnet mask default gateway username and password will remain as configured by the user Click Default Factory Default interface System Reboot Reboot the Switch Click Reboot System Reboot interface ...

Page 61: ...e to filter The packet types have are all packet types broadcast multicast unknown unicast packets broadcast multicast packets and broadcast packet only The broadcast multicast unknown unicast packet broadcast multicast packet and broadcast packet only are only for ingress The egress rate only supports all packet types Band Width Ports 1 through 8 support port ingress and egress rate control For e...

Page 62: ...NOTE 1 If the configuration is not saved it will be lost when the switch is powered off 2 QoS and Rate control cannot exist at the same System Log Set up system log events and view the system log events System Log Use to view the system events Click Reload button to get newest system log event To clear the log events click Clear Drag down the page list to switch to a different page System Log Clie...

Page 63: ...uration Select the system log events When a selected event occurs the system will log the information System event selection 4 selections Cold start Power status SNMP Authentication Failure and X Ring topology change Mark the checkbox to select the event Device cold start A log entry will be made when the switch is cold started Power status A log entry will be made when the power status changes i ...

Page 64: ...www bb europe com X Ring topology change A log entry will be made when the X Ring topology changes Port event selection Select port specific events to log 3 selections Link UP Link Down and Link UP Link Down Link UP The system will produce a log message when the port comes up Link Down The system will produce a log message when the port connection goes down Link UP Link Down The system will produc...

Page 65: ...land Ph 353 91 792444 Fax 353 91 792445 www bb europe com Trouble shooting Verify the power supply is correct 12 to 48 VDC Do not exceed 48 VDC Ensure the proper cable is used for RH 45 connections 100Ω Category 3 4 or 5 cable for 10Mbps connections or 100Ω Category 5 cable for 100Mbsp connections Ensure the length of any twisted pair connection does not exceed 328 feet 100 meters LED Indicators a...

Page 66: ...ing Standard IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX and 100Base FX Fast Ethernet IEEE802 3x Flow Control and Back pressure IEEE802 1d spanning tree IEEE802 1w rapid spanning tree IEEE802 1p class of service IEEE802 1Q VLAN Tag Protocol CSMA CD Management SNMP management Web interface management One default button for system default setting SNMP MIB RFC 1213 MIBII RFC 1493 Bridge MIB R...

Page 67: ...rm configuration Fault alarm X Ring Technology Store and forward switching architecture Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port Transfer packet size 64bytes to 1522 bytes with VLAN tag Packet filter 4 types of packet filter rule with different packet combination All of packet Broadcast multicast unknown unicast packet Broadcast multicast...

Page 68: ...e 50 125um or 62 5 125um SC Single mode 9 125um Available distance 2KM Multi mode 30KM single mode Wavelength 1310nm multi mode single mode Back plane 1 6Gbps Packet throughput ability 1 19Mpps 64bytes Power Supply 12 48 VDC Redundant power with polarity reverse protects function and connective removable terminal block for master and slave power Power consumption 7 68 Watts X Ring 2 ports for X Ri...

Page 69: ...e determined by port Tag and Ipv4 Type of service Spanning tree IEEE802 1d spanning tree IEEE802 1w rapid spanning tree IGMP IGMP v1 and Query mode Up to 256 groups SMTP Supports SMTP Server and 4 e mail accounts for receiving event alert SNTP Support SNTP to synchronize system clock in Internet Management IP security IP address security to prevents unauthorized intruder Port mirror TX packet only...

Page 70: ...on rule for Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The ingress packet filter rate can be set follow as 1Mbps 2Mbps 4Mbps 8Mbps 16Mbps 32Mbps 64Mbps DHCP client DHCP client function to obtain IP address from DHCP server Install DIN rail kit and wall mount ear for wall mount or DIN type cabinet install Operation Temp Wide Operati...

Page 71: ... 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 Stability testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration ...

Reviews: